ALARM PROGRAMMING

Alarmed cameras can be displayed on one or several monitors as part of one or several alarm groups (each monitor can display only one alarm group).

Before programming alarm settings note the following precautions:

Verify that no automated system functions are set to run, such as a macro that would arm or disarm an alarm.

Ensure that system operators do not arm or disarm any alarms while you are programming alarm settings.

NOTE: You cannot access the Alarm Contacts screen when an alarm is active. If an alarm is triggered while you are in the CM6800 programming screens, the system will exit the on-screen programming function and display the alarm on the appropriate monitor(s).

Complete the following steps to program alarms:

1.Program the alarm display format for each alarm group. An alarm can include up to eight steps, so eight camera views could display as a part of each alarm. Refer to Program Alarm Groups.

2.Program the individual alarm contact. Refer to Program an Internal or External Alarm Contact.

3.Optional: Assign a logical alarm number to the alarm contact. Refer to Assign a Logical Alarm Number.

PROGRAM ALARM GROUPS

Use the Alarm Group screen to configure alarm groups to appear on system monitors.

PELCO SWITCHER

 

 

 

ALARM MONITOR GROUP SETUP

 

 

MODEL CM6800E

 

 

 

 

 

 

 

 

MAIN MENU

 

ALARM CONTACTS

MON

A

B C D E F

G

H

1

CAMERA

 

 

 

 

 

 

2

LOGICAL CAMERA

 

 

01

— — — — — — — —

3

MONITOR

1

INTERNAL CONTACT

02

— — — — — — — —

4

ACCESS

2

EXTERNAL CONTACT

03

— — — — — — —

5

TIME & DATE

6

PORT

3

VIDEO LOSS

04

D

— — — — — — —

7

PRIORITY

4

ALARM GROUP

05

Q

— — — — —

8

SEQUENCE

5

LOGICAL ALARM NUMBER

06

— — — — S

9

MACRO

07

— — — — S

 

 

10

ALARM CONTACTS

 

 

08

— — — — S

11

EVENT TIMER

 

RETURN

 

 

 

 

 

 

12

SET AUXILIARY

 

 

 

 

HELP

 

 

13

SET PASSWORD

 

 

 

 

 

 

14

SYSTEM

 

 

 

 

 

 

 

15

ABOUT CM6800E

 

 

 

 

RETURN

 

 

ENGLISH

RETURN

Figure 34. Program Alarm Groups

Specify the display option for each alarm group. Refer to the on-screen Help or to the Alarm Group Display Options section in the Appendix for a descripton of each display option.

Display Option Entry

Display Option Type

Number of Monitors Displaying Each Alarm Group

 

 

 

B

block build

up to eight (96 x 16 system: up to 16)

 

 

 

D and Q

chronological pair

one display monitor (D), one queue monitor (Q)

 

 

 

M and L

reverse chronological pair

one display monitor (M), one queue monitor (L)

 

 

 

S

Salvo group

from two to eight (96 x 16 system: from two to 16)

 

 

 

C1528M-F (6/05)

45

Page 45
Image 45
Pelco CM6800E-48X8 manual Alarm Programming, Program Alarm Groups