PORTS (SERIAL/COM PORTS)

Use the Port screen to configure the settings for each device connected to a Serial/COM port on the rear panel of the CM6800E.

PELCO SWITCHER

MODEL CM6800E

MAIN MENU

1

CAMERA

SET SERIAL PORT 05

2

LOGICAL CAMERA

 

 

3

MONITOR

DEVICE:

KBD300

4

ACCESS

TYPE:

RS485

5

TIME & DATE

6

PORT

 

BAUD RATE:

9600

 

7

PRIORITY

PARITY:

ODD

8

SEQUENCE

DATA BITS:

8

9

MACRO

STOP BITS:

1

10

ALARM CONTACTS

11

EVENT TIMER

REPORT ALARMS:

- - -

12

SET AUXILIARY

 

 

13

SET PASSWORD

RETURN

 

14

SYSTEM

 

15

ABOUT CM6800E

 

 

ENGLISH

RETURN

Figure 46. Port Screen

1.Select the number of the desired Serial Port/COM port (01-10). The serial port numbers correspond to the communication ports on the CM6800E rear panel as follows:

Serial Port

Input on CM6800E rear panel

01

COM 1 (accessed through either the DB9 input or RJ-45 port)

02-08

COM 2-8 RJ-45 inputs

09

PTZ-A control input

10

PTZ-B control input

 

 

2.Select the device connected to the COM port; the values in the TYPE, BAUD RATE, PARITY, DATA BITS, and STOP BITS fields change to the settings appropriate for the specific device.

NOTE: “KBD300” is used to refer to the KBD100, KBD200A, and KBD300A keyboards.

3.Optional: Some device options allow a choice of communication type, baud rate, and/or parity rate. If this is the case, select the desired settings.

4.Optional: If you select an ASCII device or if you use the CM6800E as a satellite device in a CM9760 system, you can select ON in the Report Alarm field to set the CM6800E to report alarms to that device. The CM6800E reports the following alarm information:

Action

ASCII text

An alarm is triggered

#Ea

An alarm is cleared

#Ia

An alarm is acknowledged

#Ka

NOTE: The alarm number (#) reported by the CM6800 is based on the logical alarm number defined in the Logical Alarm Number screen. Refer to Assign a Logical Alarm Number in the Alarm Programming section.