MON/ALM NUMBER: Enable (ON) or disable (OFF) on-screen display of the monitor/alarm number. During normal operation, the monitor number appears in this field. The monitor number is a fixed number, representing an actual BNC output on the rear panel of the CM6800E. When an alarm is active, the logical alarm number appears in this field.

MON/ALM STATUS: Enable (ON) or disable (OFF) on-screen display of the monitor or alarm status.

MONITOR STATUS DISPLAY VALUES:

Blank = normal status

H = hold

S = sequence

0001 E CAM 1

0001 01-JAN-01 01:01:01

0001 E CAM 1

0001 01-JAN-01 01:01:01

 

NOTE: If an operator presses the HOLD key while an alarm

 

appears on the monitor, the H does not appear. The alarm icon

 

and alarm status value blink to indicate the HOLD status.

 

 

 

ALM STATUS DISPLAY VALUES:

 

I = internal alarm

 

E = external alarm

 

V = video loss alarm

TIME:

Enable (ON) or disable (OFF) on-screen display of the time as

 

programmed in the system.

V

0001

E

CAM 1

0001

V

01-JAN-01 01:01:01

0001 E CAM 1

0001 01-JAN-01 01:01:01

DATE:

Enable (ON) or disable (OFF) on-screen display of the date as

 

 

programmed in the system.

 

BRIGHTNESS:

Select the brightness level of the on-screen display (1-8; 8 = white characters, 1 = black characters; 2-7 = shades

 

of gray).

 

 

If you select CURRENT in the MONITOR field, you can see the brightness level change as you scroll through the

 

options.

 

 

If you select ALL in the MONITOR field, the changes do not take effect until you apply changes in the SET ALL

 

field.

 

POSITION DISPLAY:

Navigate left or right to select the Test Positioning Menu.

 

 

The real-time camera display appears with Test Positioning Menu text

---TEST POSITIONING MENU ---

 

superimposed on the screen. Use the position keys or joystick to move the

PRESS PGM EXIT

 

 

 

text to the desired position on the screen. The text moves one line or

 

 

character position at a time.

 

 

Press the PGM key to exit the test positioning menu.

 

SET ALL:

To apply monitor display changes to all system monitors (if you selected ALL in the MONITOR field) you must

 

navigate left or right in the SET ALL field; otherwise monitor display settings are not changed.

If you selected CURRENT in the MONITOR field, navigating left or right in the SET ALL field has no effect.

C1528M-F (6/05)