ALARMS

The CM6800E provides numerous alarm handling options. Refer to the Programming section for a detailed description.

1.Connect wires from the sensors to the respective alarm input points on the connectors at the back of the CM6800E. Each sensor requires two wires – one wire to the alarm input terminal and a return wire to one of the ground terminals on the connector. The CM6800E supports eight internal alarms.

Alarm sensors can be either N.O. (normally open) or N.C. (normally closed) contacts. The CM6800E is set to N.O. as a factory default.

2.If your system requires more than eight alarms, connect an ALM2064 unit to the system. Refer to the M Devices section.

96 x 16 System Alarm Capacity

Main unit: Alarms 1-8

Expansion Unit: Alarms 9-16