Satellite Alarms (Optional)

1.Enable the appropriate internal and external alarm contacts. Refer to the Alarm Contacts section for detailed instructions.

 

 

 

 

 

INTERNAL ALARM MENU

 

 

 

 

CONTACT:

1

 

 

 

 

ENABLE:

OFF

 

 

 

ACK TYPE:

MANUAL

 

 

 

TIME OUT:

10

 

 

 

TYPE:

 

NO

 

 

 

 

PRIORITY:

0

 

 

 

STP

CAM

DWL

CMD

 

##

AUX

##

 

 

 

1

0001

01

 

PRES

 

13

— — — —000

 

 

 

2

0001

00

 

— — — — 00

— — — —000

 

 

 

3

0001

00

 

— — — — 00

— — — —000

 

 

 

4

0001

00

 

— — — — 00

— — — —000

PELCO SWITCHER

 

5

0001

00

 

— — — — 00

— — — —000

 

6

0001

00

 

— — — — 00

— — — —000

 

MODEL CM6800E

 

7

0001

00

 

— — — — 00

— — — —000

 

MAIN MENU

 

8

0001

00

 

— — — — 00

— — — —000

 

 

ALARM CONTACTS

 

 

 

 

 

 

 

 

 

1

CAMERA

 

 

GROUP ENABLE

 

 

2

LOGICAL CAMERA

 

 

 

 

 

 

 

A

B

C

D

E

F

G

H

 

3

MONITOR

1

INTERNAL CONTACT

 

Y

N

N

N

N

N

N

N

 

4

ACCESS

 

2

EXTERNAL CONTACT

 

 

 

 

 

 

 

 

 

5

TIME & DATE

 

 

RETURN

 

 

 

 

6

PORT

3

VIDEO LOSS

 

 

 

 

 

 

 

 

 

7

PRIORITY

4

ALARM GROUP

 

 

 

 

 

 

 

 

 

8

SEQUENCE

5

LOGICAL ALARM NUMBER

 

 

 

 

 

 

 

 

 

9

MACRO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

ALARM CONTACTS

 

 

 

 

 

 

 

 

 

 

 

11

EVENT TIMER

 

RETURN

 

EXTERNAL ALARM MENU

 

12

SET AUXILIARY

 

CONTACT:

001

 

 

 

 

ENABLE:

OFF

13

SET PASSWORD

 

 

 

 

 

 

ACK TYPE:

MANUAL

 

 

 

TIME OUT:

10

14

SYSTEM

 

 

 

 

 

PRIORITY:

0

 

 

 

 

 

 

 

15

ABOUT CM6800E

 

 

 

 

 

 

 

 

 

STP

CAM

DWL

CMD

 

##

AUX

##

 

ENGLISH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN

 

1

0001

00

 

— — — — 00

— — — —000

 

 

 

2

0001

00

 

— — — — 00

— — — —000

 

 

 

3

0001

00

 

— — — — 00

— — — —000

 

 

 

4

0001

00

 

— — — — 00

— — — —000

 

 

 

5

0001

00

 

— — — — 00

— — — —000

 

 

 

6

0001

00

 

— — — — 00

— — — —000

 

 

 

7

0001

00

 

— — — — 00

— — — —000

 

 

 

8

0001

00

 

— — — — 00

— — — —000

 

 

 

 

 

GROUP ENABLE

 

 

 

 

 

 

A

B

C

D

E

F

G

H

 

 

 

 

 

N N

N

N N N N N

 

 

 

 

 

 

 

RETURN

 

 

 

 

Figure 56. Enable Alarm Contacts

2.In the appropriate Logical Alarm Number screen, assign a logical number for each alarm contact, in sequential order. The logical numbers assigned in this screen are reported to the CM9740/CM9760 system and they must match the physical numbers configured in the CM9740/CM9760 system (refer to Program the Alarms File in the CM9740/CM9760 System Settings section). These numbers are used by the CM9760-KBD keyboard to arm or acknowledge an alarm.

LOGICAL ALARM NUMBER CONSIDERATIONS:

If you set the CM6800E to report any CM6800E alarms to the CM9740/CM9760 system, you must assign each CM6800E alarm a logical alarm number that is unique within the CM9740/CM9760 system (i.e. when used as a satellite device, the CM6800E shares the same pool of logical alarms numbers as the CM9740/CM9760 system).

To configure a CM6800E alarm(s) to report only within the CM6800E system, and not to the CM9740/CM9760 system, assign the alarm(s) a logical alarm number of 0. When the alarm(s) is triggered, the physical number of the alarm(s) appears on the CM6800E system monitor(s).

LOGICAL ALARM NUMBER MENU

LOGICAL INTERNAL ALARM

1

LOGICAL INTERNAL ALARM

PHY

LOG

2

LOGICAL EXTERNAL ALARM

1

0001

3

LOGICAL VIDEO LOSS

2

0002

 

 

 

RETURN

3

0003

 

4

0004

 

 

 

 

5

0005

 

 

6

0006

 

 

7

0007

 

 

8

0008

RETURN

Figure 57. Assign Satellite Logical Alarm Numbers

3.Configure a CM9760-MGR Alarms file for each satellite alarm. Refer to CM9740/CM9760 System Settings in this section.

82

C1528M-F (6/05)

Page 82
Image 82
Pelco CM6800E-48X8 manual Satellite Alarms Optional, Enable Alarm Contacts