CM6800E PROGRAMMING MODE

1.If you have not already done so, select the monitor (KBD960/KBR960: if the Camera menu appears, press to exit).

2.Press the PGM key (or select PGM on the KBD960/KBR960). The Password screen appears.

Note that on the KBD960/KBR960 you must first select and DEF . Then enter the Define PIN (Default: 1234), and select MENU .

NOTE: When using the CM6800E as a satellite device in a CM9760 system, you can access the CM6800E programming screens from the CM9760-KBD keyboard if you are viewing a camera controlled by the CM6800E. Refer to the Using the CM6800E as a Satellite Device in a CM9740/CM9760 System section in the Appendix.

Figure 31. CM6800E Password Screen

PELCO VIDEO SWITCHER

MODEL CM6800E

PASSWORD TO MAIN MENU

*******

SCRATCHPAD SEQUENCE MACRO STATUS VIEW RETURN

3.At the ******* prompt, enter the DEFAULT PASSWORD: 2899100 The Main Menu appears.

Figure 32. CM6800E Programming Main Menu

PELCO SWITCHER

MODEL CM6800E

MAIN MENU

1CAMERA

2LOGICAL CAMERA

3MONITOR

4ACCESS

5TIME & DATE

6PORT

7PRIORITY

8SEQUENCE

9MACRO

10ALARM CONTACTS

11EVENT TIMER

12SET AUXILIARY

13SET PASSWORD

14SYSTEM

15ABOUT CM6800E

ENGLISH

RETURN

Select Language

If necessary, select the appropriate language.

1.Navigate to the language displayed below the menu options.

2.Scroll through the languages and select the language appropriate for your system.

3.Navigate to the RETURN field and navigate left or right to return to the Main Menu.

Exit Programming Mode