Line Service Commands

<IP_address>

Specify the IP address of the remote host that is receiving the vmodem connection.

<TCP_port>

Specify the TCP port that the remote host is lisening on for the vmodem connection.

delete

Deletes the specified entry from the phone number table.

Set Modbus-Slave Line

Description

Sets the Modbus slave parameters for the line.

User Level

Admin

Syntax

set modbus-slave line .<number>* [crlf onoff]

 

[protocol rtuascii] [uid-range <uid_range>]

Options

crlf

 

When Modbus/ASCII is selected, adds a CR/LF to the end of the transmission; most

 

Modbus devices require this option. The default is On.

 

protocol

 

Specify the protocol that is used between the Modbus Master(s) and Modbus Slave(s),

 

either RTU or ASCII.

 

uid-range

 

You can specify a range of UIDs (1-247), in addition to individual UIDs. The format is

 

comma delimited; for example, 2-35, 50, 100-103.

Set Modbus-Master Line

Description

Sets the Modbus master parameters for the line.

User Level

Admin

Syntax

set modbus-master line .<number>* [crlf onoff]

 

[protocol rtuascii]

 

[[entry <number> [port <port>] [protocol udptcp]

 

[range-mode gatewayhost] [slave-ip <IP_address>]

 

[uid-range <start_uid> <end_uid>]]

Options crlf

When Modbus/ASCII is selected, adds a CR/LF to the end of the transmission; most

Modbus devices require this option. The default is On.

protocol

Specify the protocol that is used between the Modbus Master(s) and Modbus Slave(s), either RTU or ASCII.

entry

You can specify up to 16 Modbus Slave Remote IP Mapping entries (the UIDs must not overlap).

port

The destination port of the remote Modbus TCP Slave that the IOLAN will connect to.

53