Set IOChannel

Set IOChannel Digital Output (Serial Pins)

Description Sets the Digital output for serial pins RTS and DTR. This option is only available when the Line Service is set to Signal I/O.

User Level Admin

Syntax set iochannel rtsdtr [description <string>] [failsafe-action noneactivate-oututdeactivate-output] [mode enableddisabled]

Options description

Provide a description of the channel, making it easier to identify. The channel description can be up to 20 characters.

failsafe-action

When there has been no I/O activity within the specified time (set in the Global

Settings) and the Failsafe Timer is triggered, you can set the Failsafe Action to:

zNone—The state of the Digital/Relay output remains the same, no change.

zActivate Output—Activates the output.

zDeactivate Output—Deactivates the output.

mode

Enables the channel, allowing the settings to become active.

Set IOChannel Relay

Description

Sets the Relay output channel settings.

User Level

Admin

Syntax

set iochannel <relay_number> output

 

[pulse continuouscounted <pulse_count>]

 

[active-to-inactive-delay <delay>]

 

[inactive-to-active-delay <delay>]

 

set iochannel <relay_number>

 

[active-signal-width <width>] [inactive-signal-width <width>]

 

[failsafe-action noneactivatedeactivate]

Options

relay_number

 

Specify the Relay channel number, for example, r2.

 

output

Specify how the channel Digital output will be handled:

zManual—You must manually activate and deactivate the output.

zPulse—When the output is activated, this configuration will cause the output to pulse (go active and inactive) at a configured rate.

zInactive-to-ActiveDelay—The channel output will remain inactive for the specified time interval after it is manually started.

zActive-to-InactiveDelay—The channel output will go inactive after the specified time interval after it is manually started.

The default is Manual.

pulse

When the Output is Pulse, you can have it pulse in a Continuous manner or specify a pulse Count (each count consists of an active/inactive sequence). The default is Continuous.

83

Page 83
Image 83
Perle Systems 5500208-41 Set IOChannel Digital Output Serial Pins, Set IOChannel Relay, Options description, Relaynumber