Line Service Commands
| protocol |
| Specify the protocol that is used between the Modbus Master and Modbus Slave(s), |
| either TCP or UDP. |
|
|
| If you specify Host, the IP address is used for the first UID specified in the range. The |
| last octect in the IPv4 address is then incremented for subsequent UID’s in that range. |
| The Host option is not applicable for IPv6 addresses. If you specify Gateway, the |
| Modbus Master Gateway will use the same IP address when connecting to all the |
| remote Modbus slaves in the specified UID range. |
| |
| The IP address of the TCP/Ethernet Modbus Slave. |
|
|
| When Range Mode is Host and you have sequential Modbus Slave IP addresses (for |
| example, 10.10.10.1, 10.10.10.2, 10.10.10.3, etc.), you can specify a UID range and the |
| IOLAN will automatically increment the last digit of the configured IP address. |
| Therefore, you can specify a UID range of |
| Modbus messages to all Modbus Slaves with IP addresses of 10.10.10.1 - 10.10.10.100. |
Set Multihost Line |
|
Description | Configures multiple hosts or a primary/backup host schema for Silent Raw, Reverse |
| Raw, or |
| service type for this to take effect, see Set Line Service on page 45 for the command to |
User Level | enable multihost). |
Admin | |
Syntax | set multihost line <number> entry <number> host <host> <TCP_port> |
| set multihost line <number> entry <number> delete |
Options | entry |
| You can specify up to 100 hosts in the multihost table. |
| host <host> |
| Specify the preconfigured host that will be in the multihost list. |
| <TCP_port> |
| Specify the TCP port that the IOLAN will use to communicate to the Host. |
| delete |
| Deletes the specified entry from the multihost table. |
Set Line | |
Description | Determines how the connection is initiated for Direct Telnet. |
User Level | Admin |
Syntax | set line <number>* |
| |
Options |
|
Initiates a connection to the specified host when any data is received by the serial port.
Initiates a connection to the specified host only when the specified character is received by the serial port.
54 | IOLAN DS1/TS2 CLI Reference Guide, Version 4.1 |