Chapter 2

Warnings, Cautions, and Notes

Notes

Follow the setup instructions in this manual before placing the Respironics V200 Ventilator into service. If you have questions, contact Respironics Customer Service at 1-800-345-644

Save the shipping container in case the backup battery has to be returned to Respironics.

We recommend that before using the ventilator for the first time, wipe the exterior clean and disinfect or sterilize its components according to the instructions in Chapter 10, “Care and Maintenance” or the component manufacturer’s instructions.

Follow institutional infection control guidelines when replacing the inspiratory or expiratory bacteria filter.

When adding attachments or other components or subassemblies to the breathing system, for example, an HME or humidifier, ensure that the inspiratory and expiratory resistances (measured at

the patient connection port) do not exceed 6 cmH2O (hPa) at a flow of 60 L/min for adults, 30L/min for pediatrics.

High humidity and aerosol medications may reduce expiratory filter life, increase expiratory resistance, and/or cause filter damage. Review ventilator patient graphics frequently for changes in expiratory resistance. Consult filter manufacturer recommendations regarding duration of use, maintenance, and removal and disposal of expiratory filter.

The ventilator should only be connected to an appropriate medical

grade 100% O2 gas source capable of delivering a regulated 40 to 90 PSIG (276-620 kPa).

The ventilator is shipped with the appropriate gas fittings and hoses for the intended environment, i.e. DISS (U.S.A. and Canada), Ohmeda (Germany), NIST (UK), Air Liquide (France), SIS (Australia).

All volumes entered into the ventilator are assumed to be BTPS

(Body Temperature atmospheric Pressure Saturated (with H2O)) volumes unless otherwise noted. All volumes reported by the ventilator are reported as BTPS volumes. All pressures are assumed to be relative to atmospheric pressure unless otherwise noted.

The Air Inlet Filter houses a reusable foam filter that should be periodically cleaned. Refer to Chapter 10, “Care and Maintenance”, for more information on filter changes.

Unless the Mains Circuit Breaker is turned OFF, electrical power is applied to the ventilator even though the front panel switch is in the OFF position. With the Mains Circuit Breaker ON, if the backup battery is connected, the ventilator will charge the battery if it requires a charge.

2-8

Respironics V200 Ventilator Operator’s Manual

REF 1057983 A

Page 18
Image 18
Philips V200 manual Chapter

V200 specifications

The Philips V200 is a robust mobile device that combines functionality with sleek design, catering to users who prioritize efficiency and modern technology. This smartphone is engineered to provide a seamless user experience, integrating advanced features and specifications that enhance daily activities.

One of the standout features of the Philips V200 is its vibrant display. The device boasts a large, high-resolution screen that renders visuals with stunning clarity and color accuracy. This makes it an excellent choice for multimedia consumption, whether you're watching videos, playing games, or viewing photos. The touchscreen interface is smooth and responsive, allowing for effortless navigation across applications.

Under the hood, the Philips V200 is powered by a reliable processor, ensuring fast performance and multitasking capabilities. With ample RAM, users can run multiple applications simultaneously without experiencing lag, making it suitable for both work and leisure. This processing power is complemented by substantial internal storage, providing enough space for apps, photos, videos, and other essential files.

Connectivity is another highlight of the Philips V200. It supports various networks and is equipped with 4G LTE capabilities, ensuring users stay connected at high speeds wherever they go. Bluetooth and Wi-Fi functionalities also enhance connectivity options, allowing easy sharing of files and media between devices.

The camera system on the Philips V200 is designed to cater to photography enthusiasts. With a high-resolution rear camera and a secondary front camera, users can capture stunning images and selfies. The device also includes several camera features such as portrait mode and various filters, making photography more enjoyable and creative.

The Philips V200 places significant emphasis on battery life, with a long-lasting battery that ensures all-day usage. Users can rely on the device for extended periods without the need for frequent charging, which is particularly useful for those with busy lifestyles.

In terms of software, the Philips V200 runs on a user-friendly operating system that provides access to a plethora of applications and services. The user interface is intuitive, making it easy for users to customize their devices according to their preferences.

Overall, the Philips V200 stands out in the competitive smartphone market by offering a well-rounded package of features, performance, and design. It is a practical choice for anyone seeking a reliable and stylish mobile device that can handle both everyday tasks and more intensive applications with ease. Whether you are a professional, a student, or simply someone who enjoys technology, the Philips V200 is engineered to meet diverse needs.