3 Operate the touch panel buttons or faders.
Transmission of the MIDI messages begin.
For messages output by this unit, see List of MIDI Messages on page 18.
Operating an external MIDI sequencer
This unit sends the tempo of the currently playing source (BPM information) as the MIDI timing clock. This can be used to synchronize an external MIDI sequencer with the tempo of the source.
!External MIDI sequencers not supporting MIDI timing clocks cannot be synchronized.
!External MIDI sequencers cannot be synchronized for sources for which the BPM cannot be measured stably.
!MIDI timing clocks are output even for BPM values input manually by tapping the [TAP] button with a finger. The MIDI timing clock output range is 40 BPM to 250 BPM.
1Connect the [MIDI OUT] terminal to the external MIDI sequencer’s MIDI IN terminal using a commercially available MIDI cable.
2Set the external MIDI sequencer’s sync mode to Slave.
3Press [START/STOP].
The MIDI start message is sent.
4 Press [ON/OFF] in the [MIDI] section.
Transmission of the MIDI messages begin.
English
En 17