Printer Menus

Using the Setup Menu (continued)

2. Feeder Signal (continued)

D. On/Quick Off

This option turns on a signal whenver one or more reocrds are in the buffer to be printed. The signal is turned off once the sensor detets the piece to print the last record of the buffer on.

E. Signal Polarity (Active On/Active Off)

This option reverses the signal used to trigger the feed- er.

Active On actives and external feeder by switching on the feeder signal.

Active Off activates an external feeder by switching the feeder signal off.

For instructions how to use the menus and select an op- tion, refer to page A-4.

3. Lines Per Address

Use this option to set the number of lines of text in the address field. It can be set from 1 to 66.

For instructions how to use the menus and select an op- tion, refer to page A-4.

4. Line Termination

This item allows the printer to interpret what the Line Termination (end of a line of text) is for different operat- ing systems or software. Choose from the various Line Termination formats to get the correct line count and then the record will print correctly.

The typical software line termination is CR = CR; LF = LF. If your software is not typical then the Line Termination can be modified. The menu choic-

es are (CR=CR;LF=LF), (CR=CR+LF;LF=LF), (CR=CR;LF=CR+LF), and (CR=CR+LF;LF=CR+LF).