Chapter 6: Technology Background

Automatic Transition

At this juncture, you would replace the failed drive in channel 2 with a new drive of the same or greater capacity.

When the SuperTrak controller detects the new drive in channel 2, it will:

Transition the data from the drive in channel 4 to the drive in channel 2.

Return the drive in channel 4 to spare status.

When the Transition is finished:

The physical drives in channels 1 and 2 belong to the disk array.

The physical drive in channel 3 is still unconfigured.

The physical drive in channel 4 is a revertible spare drive.

The original configuration is restored.

Manual Transition

Manual transition requires an unassigned physical drive.

The example below is the same two-drive RAID 1 disk array as before.

The physical drives in channels 1 and 2 belong to the disk array.

The physical drive in channel 3 is unconfigured.

The physical drive in channel 4 is a revertible spare drive.

187

Page 199
Image 199
Promise Technology EX8650A, EX4650A user manual Automatic Transition, Manual Transition