Problem

Troubleshooting Suggestion

Cannot access the Configuration

Use the ping utility to check whether your PC can communicate with

Manager program from your

the ADSL Router’s LAN IP address (by default 192.168.1.1). If it cannot,

browser.

check the Ethernet cabling.

 

Verify that you are using Internet Explorer v5.0 or later, or Netscape

 

Navigator v4.7 or later. Support for Javascript® must be enabled in

 

your browser. Support for Java® may also be required.

 

Verify that the PC’s IP address is defined as being on the same subnet

 

as the IP address assigned to the LAN port on the ADSL Router.

 

 

Changes to Configuration

Be sure to use the Commit function (Admin > Commit & Reboot) after

Manager are not being retained.

any changes.

Upgrading

Error Message

Possible cause

Action

invalid checksum

The firmware file to be used is

Make sure that your firmware file format is

 

damaged or the file format is wrong.

valid or get a new firmware file.

 

 

 

invalid hardcode

The firmware file is not compatible

Download a compatible firmware from the

 

with the model of your ADSL Router.

Web.

 

 

unknown flags type

The firmware version is not compatible. Download a compatible firmware from the

 

 

Web.

 

 

 

internal isfs error /

System error occurs. It may cause by

Reboot your ADSL Router and perform the

internal flashfs error

the lack of memory.

upgrade task again.

invalid file format

The firmware file format is invalid.

Check the file format is correct, otherwise download a firmware file with correct format.

get an error message The TFTP server responses with error message.

Make sure the file name you enter is correct. Otherwise the TFTP server may response with the error message “File not found”.

transfer time out

The transfer session is interrupted.

a. Make sure the TFTP server is on the

 

 

 

same subnet with the ADSL Router.

 

 

b.

Make sure you the IP address of the

 

 

 

TFTP server you specify is correct and

 

 

 

that your TFTP server is started.

 

 

c.

If error still occurs, reboot your ADSL

 

 

 

Router and perform the upgrade task

 

 

 

again.

 

 

 

firmware update in

The upgrade is already in process

Do not turn off your ADSL Router

process

 

otherwise you will cause damage to the

 

 

device

 

 

 

no remote server IP

The IP address of the TFTP server is not

Specify the IP address of the TFTP server is

 

specified

not specified.

 

 

 

can’t allocate update

It may cause by the lack of memory.

Reboot your ADSL Router and perform the

buffer

 

upgrade task again.

 

 

 

 

80

Rev:01_040220

Page 86
Image 86
Siemens E-110-I user manual Problem Troubleshooting Suggestion, Upgrading Error Message Possible cause Action