AirborneDirect™ Users Guide | Quatech, Inc. |
|
|
Table 2 - Serial Ports by Product Class
Device Class
Port 1
Port 2
Enterprise
Industrial
RS232
RS422
RS485
RS232
RS422
RS232
RS422
N/A
N/A
RS232
RS422
The Port 1 and Port 2 interfaces support the following configurations:
BAUD: 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200, 230400, 460800, 921600
Flow Control: None, Hardware (CTS/RTS), Software (XON/XOFF)
Port 1 Default settings: 9600, 8, N, 1, No Flow Control.
Port 2 Default settings: 9600, 8, N, 1, No Flow Control.
6.2Ethernet Port
The AirborneDirect™ Ethernet devices support a single interface. This is a 10/100Mbps interface that supports auto negotiation and
Figure 7 - Ethernet Jack Pin Out
Table 3 - Ethernet Connector Pin Out
Pin
RJ45 Socket (Industrial)
RJ45 Plug (Enterprise)
1
2
3
4
5
6
7
TxD+
TxD-
RxD+
NC
NC
RxD-
NC
RxD+
RxD-
TxD+
NC
NC
TxD-
NC