12.0 Configuring Device – Industrial Serial (ABDG-SE-IN5XXX)

The following describes initial connection to an AirborneDirect™ Serial Device Server (ABDG-SE-IN5XXX). If you have an Ethernet device (ABGD-ET-DP5XX/IN5010), please go to section 14.0. If you have purchased a SE-DP5XX device please go to section 13.0 for the set-up instructions.

The instructions in Table 14 provide step-by-step instructions for configuration of the ABDG-SE-IN5XXX product family.

Table 14 - SE-IN5XXX Accessing the Web Interface

1

2

3

4

5

Open the AirborneDirect™ packaging and locate the Install CD.

Place the CD in the CD/DVD drive of the laptop or desktop you will be using to configure the AirborneDirect™ device. Follow the on screen directions for installation of the appropriate device software and documentation.

Connect the Ethernet cable on ABDG to an Ethernet port on the laptop or desktop system.

Apply power to the ABDG-SE-IN5XXX.

The unit will boot and display one of the following LED patterns:

ABDG-SE-IN5XXX

 

COMM:

Off

LINK :

Off

POST:

Orange

POWER:

Blue

Run the Airborne Management System application. This was installed during the CD installation and a menu item will be found in the Airborne folder located in the programs directory of your system.

When the application opens the following dialog will be displayed:

6

Select Group Name: manuf and enter Group Password: dpac

100-8510-110

2/21/2011

35

Page 35
Image 35
Quatech HD500, IN5000, DP500 Configuring Device Industrial Serial ABDG-SE-IN5XXX, SE-IN5XXX Accessing the Web Interface