Replacing the Maintenance Kit

Replacing the Fusing Unit

RCAUTION:

The fusing unit becomes very hot. When installing the new fus- ing unit, turn off the printer and wait about an hour. After that, in- stall the new fusing unit. Not waiting for the unit to cool down can result in a burn.

C Lift the lock levers of the fusing unit as shown in the illustration.

2

AGN006S

Replacing the fusing unit
D Pull the fusing unit out.A Open the rear cover by pushing the two knobs.

AGN004S

B Remove the rear cover in a horizontal direction.

AGN007S

E Pull out the pins on both sides of the new fusing unit.

ZKGM010E

ZKGX220E

39