USING THE MENU SCREEN

OPTION/RS-485

ADDRESS setting

If the ADDRESS setting on the screen is 0, this means that the camera’s RS-485 address is currently set to 0. If the address is changed using the address setting switches at the side of the camera as shown in the illustration, the new address will be displayed on the screen.

TERMINATE setting

The DIP switches need to be set when a computer, special controller, etc. connected to the RS-485 connectors is used to control the camera. Make sure to turn the camera power off before setting the DIP switches.

About SW No.

1-7:To setup the camera address (only when using the RS-485 connector).

Switch 1 is the least significant bit (LSB) and switch 7 the most significant bit (MSB) (Down: 0,

Up: 1). This setting is done according to a binary code.

8:To setup the termination (only when using the RS-485 connector). OFF side (down): Not terminated

ON side (up): Terminated

Returning the values to the default settings

Press the CURSOR (l, then d or c) button to change the PRESET setting to ON, then press the SET button.

When finished

Press the CURSOR (l) button to select BACK (it will flash) at the bottom of the screen. Then press the CURSOR (d or c) button to change BACK to END, and press the SET button.

To return to the previous screen, select BACK then press the SET button.

MENU FOR RS-485

CURSOR

SET

19200

 

BAUD RATE

 

ALARM

ON

 

ADDRESS

0

(ADDRESS SET)

ON

ON

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

TERMINATER ON/OFF

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

CURSOR

SET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

BACK

 

 

 

 

 

 

MENU

END

English 57

Page 58
Image 58
Sanyo VCC-6974 instruction manual Address setting, Terminate setting, About SW No