106 BBV28581 05/2010
Migration ATV11 - ATV12
Functions - Comparison with ATV11pppE327 versionsFunction ATV11 ATV12 Comments, Action
Code value Code value
Frequency bFr 50 bFr 50 No change.
High Speed HSP 50 HSP 50 No change.
LI operation Logic - (Positive) nPL POS "Depend on LI assignment on each function (LI1 to
LI4 L or H).
See function assignment page 51"
Integrated EMC filter - Yes - Yes "Possible to disable filter using IT jumper. See page
28."
Li assignment LI1 Forward LI1 Forward No change.
LI2 Reverse LI2 - Change rrS (COnF, FULL, Fun, rrS), LI2.
LI3 2 Preset
speeds
LI3 - Change PS2 (COnF, FULL, Fun, PSS, Pr2), LI3.
LI4 4 Preset
speeds
LI4 - Change PS4 (COnF, FULL, Fun, PSS, Pr4), LI4.
Speed reference SP2 10 SP2 10 No change.
SP3 25 SP3 15 Change SP3 (COnF, FULL, Fun, PSS, SP3), 25.
SP4 50 SP4 20 Change SP4 (COnF, FULL, Fun, PSS, SP4), 50.
AO assignment (dO,
ACt),
rFr
Motor
frequency
AO1 - Change AO1 (COnF, FULL, I-O, AO1-,AO1), OFr.
AI assignment (AIt,
ACt), 5U
Speed ref.
5V
AI1t Speed ref.
5V
No change.
Command channel LSr LOC Fr1 AI1 Change FR1 (COnF, FULL, CtL-, FR1), AIU1.
(tCC,
Act),
LOC
Local control
(RUN /
STOP)
CHCF SIM No change.
Cd1 -
Motor parameter
choice
COS Acc. to rating COS - COS is visible only if Motor parameter choice "MPC"
is set to COS.
Change MPC (COnF, FULL, drC-, MPC), COS.
Change COS (COnF, FULL, drC-, COS), Acc. To
rating.
Motor control type unchangeabl
e
SVC Ctt STD (U/F) Change CTT (COnF, FULL, drC-, CTT), PERF
(SVCU).
Application
Underload time
delay
tUL 5ULt 0 The function is deactivated in factory setting.
Application
Overload time delay
tOL 5OLt 0 The function is deactivated in factory setting.