Monitoring mode MOn
Code Name/Description
StAt M Product status
This parameter shows the state of the drive and motor.
rdY
rUn
ACC
dEc
dCb
CLI
nSt
Obr
CtL
tUn
FSt
nLP
FrF
rEM
LOC
vDrive ready
vDrive running, the last six segments to the right of the code also indicate direction and speed.
vAcceleration, the last six segments to the right of the code also indicate direction and speed.
vDeceleration, the last six segments to the right of the code also indicate direction and speed.
vDC injection braking in progress
vCurrent limit, the four segments located on right down of display are blinking.
vFreewheel stop control
vAuto-adapted deceleration
vControlled stop on mains phase loss
vAuto-tuning in progress
vFast stop
vNo line power. When the control part is energized via the RJ45 connector and there is no power on the
main input and no run order is present.
vDrive is running and using the withdrawal reference LFF
vRemote configuration
vLocal configuration