BBV28581 05/2010 125
Parameter index
Code Page Name Unit Possible value / Function Factory setting User
setting
HSP4 90 High speed 4 Hz as HSp2 as HS2 as HSp2
HSU 41 Display of high speed value - - - - -
InH 95 Detected fault inhibition
assignment
nO
L1H
L2H
L3H
L4H
Non active
L1h: LI1 active high
L2h: LI2 active high
L3h: LI3 active high
L4h: LI4 active high
nO
IPL 94 Input Phase loss - nO
YES
No
Yes YES
Ith 94 Motor thermal current A 0.2 to 1.5 -according to
drive rating
JOG 68 Jog assignment
nO
L1H
L2H
L3H
L4H
No
L1h: LI1 active high
L2h: LI2 active high
L3h: LI2 active high
L4h: LI4 active high
nO
JPF 70 Skip frequency Hz 0 to 400 -0 Hz
LC2 88 2nd current limitation
commutation
nO
L1H
L2H
L3H
L4H
L1L
L2L
L3L
L4L
No
L1h: LI1 active high
L2h: LI2 active high
L3h: LI3 active high
L4h: LI4 active high
L1L: LI1 active low
L2L: LI2 active low
L3L: LI3 active low
L4L: LI4 active low
nO
LCr 39 Motor current A - - - -
LFd 79 Zero flow detection offset Hz 0 Hz
LFF 76 Fallback speed Hz 0 Hz
LFL1 95 4-20 mA loss behavior nO
YES
No
Yes nO
LFr
39
45
62
External reference value - -400 to 400 -0
LIS1 41 State of logic inputs LI1 to LI4 - - - - -
LOC 54
77 Application Overload threshold % of
NCR 70 to 150 - 90 %
LO1 53 LO1 assignment as r1 as r1 nO
LO1S 53 LO1 status (output active level) POS
nEG
Positive
Negative POS
LOS1 41 State of the logic output LO1
and relay R1 -- - - -
LPI 76 PI feedback supervision
threshold nO
LSP 45
89 Low speed Hz 0 to HSP -0 Hz