122 BBV28581 05/2010
Parameter index
Code Page Name Unit Possible value / Function Factory setting User
setting
AC2 65
74 Acceleration 2 s 0.0 to
999.9 -5 s
ACC 45
64 Acceleration s 0.0 to
999.9 - 3.0 s
AdC 67 Automatic DC injection
nO
YES
Ct
No
Yes
Continuous
YES
Add 97 Modbus address OFF to 247 -Off
AIIt 52 AI1 type -
5U
10U
0A
Voltage
Voltage
Current
5U
AIU1
37
39
45
62
Analog input virtual % 0 to 100 --
AO1 56 AO1 assignment
nO
OCr
OFr
OrP
OPS
OPF
OPE
OPr
tHr
tHd
No
Motor current
Output frequency
Ramp output
PID reference
PID feedback
PID error
Output power
Motor thermal state
Drive thermal state
nO
AO1t 56 AO1 type
10U
OA
4A
Voltage
Current
Current
0A
Atr 91 Automatic restart nO
YES
No
Yes nO
bFr 45
57 Standard motor frequency Hz 50
60 -50 Hz
brA 65 Decel Ramp Adaptation
assignment
nO
YES
dYnA
No
Yes
Motor braking
YES
C1SU 41 Card 1 Software Version - - - - -
C2SU 41 Card 2 Software Version - - - - -
Cd1 63 Commandchannel 1
tEr
LOC
LCC
Mdb
Terminals
Local
Remote display
Modbus
CFG 47 Macro-configuration - - - - -
CHCF 62 Channel configuration SIM
SEP
Simultaneous mode
Separate mode SIM
CLI 88 Current limitation A 0.25 to 1.5 -1.5 A