BBV28581 05/2010 129
Parameter index
Code Page Name Unit Possible value / Function Factory setting User
setting
rP2 73 2 preset PID reference % 0 to 100 -25%
rP3 73 3 preset PID reference % 0 to 100 -50%
rP4 73 4 preset PID reference % 0 to 100 -75%
rPC 39 PID reference - - - - -
rPE 39 PID error - - - - -
rPF 39 PID Feedback - - - - -
rPG 72 PID proportional gain 0.01 to 100 -1
rPH 73 PID max value reference % PID 0 to 100 - 100%
rPI 73 Internal PID reference % PID 0 to 100 -0%
rPL 73 PID min value reference % PID 0 to 100 -0%
rPr 96 Reset power run nO
FtH
Function inactive
Reset fan time display
nO
rPS 64 Ramp switching
commutation
nO
L1H
L2H
L3H
L4H
L1L
L2L
L3L
L4L
No
L1h: LI1 active high
L2h: LI2 active high
L3h: LI3 active high
L4h: LI4 active high
L1L: LI1 active low
L2L: LI2 active low
L3L: LI3 active low
L4L: LI4 active low
nO
rPt 64 Ramp shape assignment
LIn
S
U
Linear
S shape
U shape
LIn
rrS 66 Reverse direction -
nOLIhL2HL3HL4H
Function inactive
L1h active high
L2h active high
L3h active high
L4h active high
nO
rSF 91 Detected fault reset
assignment -
nO
L1H
L2H
L3H
L4H
No
L1h: LI1 active high
L2h: LI2 active high
L3h: LI3 active high
L4h: LI4 active high
nO
rSL 75 PID wake up level % 0 to 100 -0%
rtHI 42 Run elapsed time display 0.01h 0.01 to 999 ---
SCS 46 Store customer parameter
set -nO
Str1
No
Yes nO
SdC1 67 Automatic DC injection
current A0 to 1.2 0.7 A
SFr 59 Switching frequency kHz 2 to 16 -12
SFS 73 PID predictive speed - nO to 400 -nO
SFt 59 Switching frequency type - HF1
HF2
HF1
HF2 HF1