88 BBV28581 05/2010
Configuration Mode - Complete menu (FULL)
(1)In = nominal drive current
Code Name/Description Adjustment range Factory setting
FUn- Function menu (continued)
CLI- Current limitation menu
LC2 M 2nd current limitation commutation nO
nO
L1H
L2H
L3H
L4H
L1L
L2L
L3L
L4L
Assignment
vFunction inactive.
vL1H: LI1 active high
vL2H: LI2 active high
vL3H: LI3 active high
vL4H: LI4 active high
vL1L: LI1 active low
vL2L: LI2 active low
vL3L: LI3 active low
vL4L: LI4 active low
If the assigned input is at 0, the first current limitation is active.
If the assigned input is at 1, the second current limitation is active.
See LI assignment information on page 46
CLI
T
M Current limitation 0.25 to 1.5 In (1) 1.5 In
First current limitation.
CAUTION

RISK OF DAMAGE TO THE MOTOR AND THE DRIVE

Check that the motor will withstand this current.
Check that the profile mission complies with the derating curve given in the installation manual.
Failure to follow this instruction can result in equipment damage.
CL2
T
M Current limitation 2 0.25 to 1.5 In (1) 1.5 In
Second current limitation
This function allows reduction of the drive current limit.
Visible only if 2nd current limitation commutation LC2 is not set to nO.
CAUTION

RISK OF DAMAGE TO THE MOTOR AND THE DRIVE

Check that the motor will withstand this current.
Check that the profile mission complies with the derating curve given in the installation manual.
Failure to follow this instruction can result in equipment damage.
TParameter that can be modified during operation or when stopped.
I-O-
drC-
CtL-
FUN-
FLt-
COM-