BBV28581 05/2010 113
Application notes2-wire control (source)
3-wire control (sink)
(a): Run Forward (b): Run Reverse
1. Connect the ground terminal to the grounding screws located below the output
terminals.
2. Connect the power terminals.
3. Connect the logic inputs.
4. Turn on the drive without giving a run command.
5. Assign factory settings to the drive, Factory / recall customer parameter set FCS
page 46 set to InI.
6. Set the motor parameters (in COnF mode) only if the factory configuration of the
drive is not suitable.
7. Perform an auto-tuning.
8. Set Reverse direction rrS parameter page 66 to LI2H
9. Start
(a): Run Forward
1. Connect the ground terminal to the grounding screws located below the output
terminals.
2. Connect the power terminals.
3. Connect the logic inputs.
4. Turn on the drive without giving a run command.
5. Assign factory settings to the drive, Factory / recall customer parameter set FCS
page 46 set to InI.
6. Set tCC to 3C see page 48
7. Set the motor parameters (in COnF mode) only if the factory configuration of the
drive is not suitable.
8. Perform an auto-tuning.
9. Set Logic inputs type nPL parameter page 51 to nEG
10. Start
LO+
LO-
COM
LI1
LI2
LI3
LI4
+24V
COM
AI1
5V
AO1
R1A
R1B
R1C
RS
UPA+ PC-PO V W
MODBUS
(a)
(b)
ConF
L2H
rrS
FUn
LO+
LO-
COM
LI1
LI2
LI3
LI4
+24V
COM
AI1
5V
AO1
R1A
R1B
R1C
RST
UPA+ PC-PO V W
MODBUS
(a)
ConF
nEG
nPL
I-O-