5. Extended setup options (67-70)

Serial error check (serial interface)

This function selects the printer's response to a serial data transmission error. The serial data transmission error includes a parity error, framing error, and over-run error. If "PRINT" is enabled, the data in error is printed as an asterisk(*). If "IGNORED" is enabled, the data in error is discarded.

67 SERIAL ERROR

S.ERROR: PRINT

S.ERROR:IGNORED

CTS signal (serial interface)

This function accepts or ignores the CTS (Clear to Send) signal from the host.

68 CTS ENABLE

CTS: NO

CTS: YES

........... Ignores the CTS signal

........... Functions according to the CTS signal from the host

CD signal (serial interface)

This function accepts or ignores the CD (Carrier Detect) signal from the host.

69 CD ENABLE

CD: NO

CD: YES

........... Ignores the CD signal

........... Functions according to the CD signal from the host

DSR signal (serial interface)

This function accepts or ignores the DSR (Data Set Ready) signal from the host.

70 DSR ENABLE

DSR: NO

DSR: YES

........... Ignores the DSR signal

........... Functions according to the DSR signal from the host