Seiko Group BP-9000 owner manual 126

Models: BP-9000

1 146
Download 146 pages 17.56 Kb
Page 134
Image 134

B. Control code summary (Setup options)

 

ITEM

Mode

 

Code & Hexadecimal

 

n (Hex.) = selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F = ITALY

(ISO-15,0I)

 

 

 

 

 

 

 

 

 

 

10 = FRANC2

FRANCE 2(ISO-25,0F)

 

 

 

 

 

 

 

 

 

 

11 = GERMN2

GERMAN 2(HP SET,OG)

 

 

 

 

 

 

 

 

 

 

12 = SPAIN2

(ISO-85,6S)

 

 

 

 

 

 

 

 

 

 

13 = SPAIN3

(HP-SET,1S)

 

 

 

 

 

 

 

 

 

 

14 = JAPAN

(ISO-14,0K)

 

 

 

 

 

 

 

 

 

 

15 = PORTU2

PORTUGAL(ISO-84,5S)

 

 

 

 

 

 

 

 

 

 

m:4 = (HP)(SECONDARY FONT)

 

 

 

 

 

 

 

 

 

 

n: 0 = LINE-DRAW

(0L)

 

 

 

 

 

 

 

 

 

 

1 = MATH-7

(0M)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[42]

Tabulation

 

 

Header w n

 

 

n: 0

= 2 characters

n: 3 = 8 characters

 

 

 

 

 

 

 

1B, 7C, 60, 02, 00, 77, n

 

 

 

 

 

 

 

 

 

 

 

1

= 4 characters

4 = 10 characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

= 6 characters

5 = 12 characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[43]

Quality

 

 

Header x n

 

 

n: 0

= LQ

n: 4 = Draft

 

 

 

 

 

 

 

1B, 7C, 60, 02, 00, 78, n

 

 

 

 

 

 

 

 

 

 

 

1

= Draft

5 = Speed draft (SD)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

= LQ

6 = Super speed draft (SSD)

 

 

 

 

 

 

 

 

 

 

3

= NLQ

7 = HQDR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[44]

Invert display

 

 

Header y n

 

 

n: 0

= No (normal)

 

 

 

 

 

 

 

 

1B, 7C, 60, 02, 00, 79, n

 

 

 

 

 

 

 

 

 

 

 

 

1

= Yes (upside-down)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[45]

Display

 

 

Header z n

 

 

n: 0 = English

n: 3 = Español

 

 

 

 

language

 

 

1B, 7C, 60, 02, 00, 7A, n

 

 

 

 

 

 

 

 

 

 

1

= Deutsch

4 = Italiano

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

= Français

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[46]

Dont save

 

 

Header [7F]

 

 

By inserting this command before the setup terminate

 

 

 

 

 

 

 

1B, 7C, 60, 01, 00, 7F

 

 

 

 

 

 

 

 

 

 

 

codes, all the setup changes are not saved in the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EEPROM but only in the current memory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 