5. Extended setup options (63-66)

Data length (serial interface)

This function selects the appropriate data length.

63 DATA LENGTH

LENGTH: 8 BITS

LENGTH: 7 BITS

Stop bit (serial interface)

This function selects the appropriate number of stop bits.

64 STOP BIT

STOP BIT: 1 BIT

STOP BIT: 2 BITS

Communication protocol (serial interface)

This function selects the appropriate communication protocol. Refer to the specification of your host system for selecting proper communication protocol.

65 PROTOCOL

PROT.: DTR

PROT.: XON/OF1

PROT.: XON/OF2

PROT.: ETX/ACK

........... BUSY/READY protocol

........... Set XON/XOFF 1

........... Set XON/XOFF 2

Note: The difference in XON/XOFF 1 and 2: XON/XOFF 1 protocol sends XON code (11h) to host system at power-on while XON/XOFF 2 does nothing.

Communication speed (serial interface)

This function selects the appropriate baud rate for the data transmission speed.

66 BAUD RT

SPEED: 38400 B

SPEED: 19200 B

SPEED: 9600 B

SPEED: 4800 B

SPEED: 2400 B

SPEED: 1200 B

SPEED: 600 B

SPEED: 300 B