UPC-E conversion rule

NSC, manufacturer’s codes (M1 M2 M3 M4 M5), and product item codes (X1 X2 X3 X4 X5) are input data.

1.

2.

NSC must be 0 or 1.

When the manufacturer’s code data is input, the rule is determined and zero

checking of the product item codes is performed.

NZ: Non-zero : 0 to 9

UCP-A Type

 

M1

M2

M3

M4

M5

X1

X2

X3

X4

X5

Rule 1

NZ

0

0

0

0

5~9

Rule 2

NZ

0

0

0

0

0

Rule 3

3~9

0

0

0

0

0

Rule 4

0~2

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

3. The following table shows print data if the rule shown above is met.

UCP-E Type

Rule 1

M1

M2

M3

M4

M5

X5

(5~9)

 

Rule 2

M1

M2

M3

M4

X5

'4'

 

Rule 3

M1

M2

M3

X4

X5

'3'

 

Rule 4

M1

M2

X3

X4

X5

M3

(0~2)

 

 

 

 

 

 

 

 

 

 

Calculating the check character

Modulus 10

a.The data at the odd-numbered position counted from the right are weighed as 3. The sum of the data character values is determined.. (The sum is determined without weighing for Postnet.)

b.The remainder of deviding the value determined in step a by 10 is determined.

c.A character having a character value equal to the remainder of subtracting the value determined in step b from 10 is the check character.