9. Bar code and enlarged character

(8) End of the bar code data sequence: ESC SO

Format:

ASCII

ESC

SO

 

Hex

1B

0E

 

Decimal

27

14

Function:

Indicates the end of a bar code data sequence.

This command is valid only when #27 BARCODE/LABEL MODE is set

to MODE 2 in the EXTENDED SETUP MODE.

(9) Bar code data sequence: DC4 DC4 B

 

 

 

 

 

 

 

 

Format:

ASCII

DC4

DC4

B

n

d1 d2 ... dk

 

Hex

 

14

14

42

n

 

 

Decimal

 

20

20

66

n

 

Function: Specifies the number (“n”) of data to be regarded as bar code data.

 

00

n

68

 

 

 

 

 

00

dk

255

 

 

 

 

00

k

 

68

 

 

 

 

If the Element is selected;

0

n, dk, k

255

 

 

This comand is valid when #27 BARCODE/LABEL MODE is set to MODE1 or

MODE2 in the EXTENDED SETUP MODE.

 

 

(10) Printing density: DC4 DC4 D

 

 

 

 

 

 

 

 

Format:

ASCII

DC4

DC4

D

 

n

 

Hex

 

14

14

44

 

n

 

Decimal

 

20

20

68

 

n

Function: Specifies the density of printing bar code symbols (in the horizontal direction).

Specifies the unit of element width.

n = 0: Bar code symbols are printed at 120 dpi. (Default value)

1:Bar code symbols are printed at 180 dpi.

If a bar code is rotated by 90 or 270 degrees using the DC4 DC4 R (bar code

rotational angle) command, a bar code is printed at 120 dpi horizontally and 180

dpi vertically.

(11) Guard bar expansion: DC4 DC4 G

 

 

 

 

 

Format:

ASCII

DC4

DC4

G

n

 

Hex

14

14

47

n

 

Decimal

20

20

71

n

Function: Specifies whether or not to expand EAN or UPC guard bars.

n = 0: Guard bars are not expanded.

1: Guard bars are expanded. (Default value)

73