9. Bar code and enlarged character
(2) Element width: DC4 DC4 E
Format: ASCII | DC4 | DC4 | E | n1 | n2 |
Hex | 14 | 14 | 45 | n1 | n2 |
Decimal | 20 | 20 | 69 | n1 | n2 |
Function: Specifies the n2/120” or n2/180” width of the element n1.
(1 ≤ n2 ≤ | 127) |
120” or 180” is specified with the DC4 DC4 D command. | |
n1 = 0: Narrow bar | 3: Wide space |
1: Wide bar | 4: |
2: Narrow space
The narrow bar width or narrow space is used as the element width for
Code 93, Code 128,
One element width of bar 1: Narrow bar width
One element width of space 1: Narrow space width
The midium bar or wide space width is used as the midium element
width for Code 11. The wide element width is (wide bar width x 2 -
narrow bar width).
This setting is not valid for Postnet.
The
bar code which begins with a bar and ends with a bar.
(3) Bar code height: DC4 DC4 H
Format: ASCII | DC4 | DC4 | H | n |
Hex | 14 | 14 | 48 | n |
Decimal | 20 | 20 | 72 | n |
Function: Sets the bar code height to n/12”. (0 ≤ | n ≤ 120) |
The currently set line feed pitch serves as the bar code height when
is set to 0. This setting is not valid for Postnet.
(4) Setting HRI on and off: DC4 DC4 I |
|
|
|
|
Format: ASCII | DC4 | DC4 | I | n |
Hex | 14 | 14 | 49 | n |
Decimal | 20 | 20 | 73 | n |
Function: Specifies whether or not to print an HRI. Also specifies the
HRI printing position if an HRI is to be printed.
n = 0: HRI not printed.
1:HRI printed below the bar code symbol.
2:HRI printed above the bar code symbol.
No HRI printed for Postnet or Element regardless of this setting.
71