UX5000U-SPSP

YF <P=001>
SPECIFICATIONS
Applicable telephone line: Public switched telephone network
Compatibility: ITU-T (CCITT) G3 mode
Configuration: Half-duplex, desktop transce iver
Compression scheme: MH, MR, MMR and Sharp special mode
Memory size*: 1MB (approx. 50 average pages )
Scanning method: Flat-bed, solid-state CCD
Resolution: Horizontal:
203 lines/inch (8 lines/mm)
Vertical:
Standard 98 lines/inch (3.85 lines/mm)
Fine /Halftone 196 lines/inch (7.7 lines/mm)
Super fine 391 lines/inch (15.4 l ines/ m m )
Printing density: Horizontal
406 lines/inch (16 lines/mm)
Vertical
391 lines/inch (15.4 lines/mm)
Reception modes: Auto/Manual switching
Modem speed: 14400 bps with au tom atic fallback to 12000, 9600, 7 200, 480 0, o r 24 00
bps
Transmission time*: Approx. 6 seconds (Sharp special mode)
Input document size: Automatic feeding:
Width 5.8 to 11" (148 to 280 mm)
Length 5.0 to 14.3" (128 to 364 mm )
Manual feeding:
Width 5.8 to 11.0" (148 to 280 mm)
Length 5.0 to 17.0" (128 to 432 mm )
Paper size: Wi dth 8.5" (216 mm)
Length 11-14" (280-356 mm)
Paper capacity: 650 sheets
Automatic document feeder: 50 documents max.
Effective scanning width: 10.1" (256 mm)
Effective record ing width: 8.0" (203 mm)
Copy function: Single/Multi-copy/Sort -copy ( 99 co pies/pag e)
Telephone function: Standard (cannot be used if power fails)
Halftone (gray scale): 64 levels
Power requirements: 120 V AC, 60 Hz
Operating environment: 50 - 86°F (10 - 30°C), 20 to 85% RH
Power consumption: Stand-by: 10 W
Maximum: 400 W
Dimensions: Width: 13.8" (351 mm)
Depth: 22.9" (582 mm)
Height: 13.7" (349 mm)
Weight: Approx. 40.8 lbs. (18.5 kg)
* Based on ITU-T Test Chart #1 at standard reso lutio n in Sha rp spe ci al mo de , ex cluding time for p rot ocol sign al s
(i.e., ITU-T phase C time only).
As a part of our policy of continuous improvement, SHARP re serves the righ t to make design and specification
changes for product improve ment without prior notice. The performance specification figure s indicated are nominal
values of production units. There m ay be some deviations from these values in individual units.

SPECIFICATIONS Spec-i