Siemens DataNET Hub (DNH) user manual DataNET Hub Specifications

Models: DataNET Hub (DNH)

1 97
Download 97 pages 44.43 Kb
Page 15
Image 15

DataNET Hub Specifications, Continued

Ambient Installation

Operation: -18° to +50°C (0° to 122°F)

Conditions

0-99% relative humidity (non-condensing) maximum

 

 

0-75% relative humidity year-round average

 

(Purge with dry air or nitrogen if required in tropical conditions.)

 

Must not be exposed to direct sunlight.

 

Must be protected from rain.

 

Storage and Transport: -25° to +65°C

Power

Nominal:

115 Vac / 230 Vac (universal input)

 

Tolerance:

85-140 Vac or 185-250 Vac; 47-63 Hz

 

 

300 watts

 

Power line protection: G fuse element per IEC 127-2, 4 A rating, slow-

 

blow

 

 

Power wiring in field made to screw terminals on two part connectors;

 

16 AWG (1.5 mm) or smaller power wiring is accepted; must conform

 

to local installation codes and requirements. If conformance to CE

 

certified installation requirements is required, power cable must be

 

shielded or installed in conduit.

Dual Hub Communication

Redundant system consisting of two identical Hub modules. Each

Modules

module consists of universal power supply and communications elec-

 

tronics and nine DataNET port connections.

Protocol and Addressing

Open Systems standard TCP/IP protocol and addressing (Transmis-

 

sion Control Protocol/Internet Protocol); Full Class A, B and C ad-

 

dresses and subnet masking supported

Uplink Port Connections

1 Uplink Port Cable or Fiber Optic Port Connection

 

Two part connectors with screw-terminals provided for cable con-

 

nection

 

 

Fiber Optic Coupler for Fiber Optic Connections

Downlink Connections

8 Downlink Cable or Fiber Optic Port Connections

 

Two part connectors with screw-terminals provided for cable con-

nection

Fiber Optic Coupler for Fiber Optic Connections

2000585-001

Introduction 7

Page 15
Image 15
Siemens DataNET Hub (DNH) user manual DataNET Hub Specifications