DataNET Hub Specifications, Continued
DataNET Option, Standard Cable
DataNET Option, Fiber Optic Cable
•Cable connection by Belden 9182 (single pair) or Belden SSD1743 (two pairs) or equivalent; two pairs of wires are re- quired to support redundancy
•Two pairs of cable is required to support redundancy
•Shielded cable or unshielded cable in conduit is required for conformance to CE certified installation
•Two part connectors with
•Fiber optics connection by 62.5
•Two pairs of fibers are required to support redundancy
•Type ST mating connectors provided for field connection
•Approximately 3 mbps base transmission rate; uses dedicated transmission technique that does not require collision detection to achieve high data throughput efficiency
Fiber Optic Coupler | Two (Tx, Rx) |
Ethernet Option | Each Hub half has an Ethernet connector but only the ‘A’ Hub half is |
| active. |
| • Cable connection by 10BaseT (twisted pair) AT&T |
| (DIW & PDS, IBM Type 3, Category 3 or 5 data ) cable |
| • Shielded cable or unshielded cable in conduit is required for |
| conformance to CE certified installation |
| • |
| • 10 mbps standard Ethernet |
| • Maximum length to adapter concentrator/hub 100m (328 ft) |
Serial Port | • Standard |
| configuring DNH IP Addresses and troubleshooting. |
8 • Introduction |