Command Descriptions, Continued

list nnn, xxx

List xxx events, starting with number nnn

 

 

list on

Continuously list events from the log buffer,

 

as they are added (terminate listing with Con-

 

trol-C)

 

 

list clear

Clear all events from log buffer

 

 

login password

Login to hub-half via the RS-232 Configura-

 

tion port

 

 

logout

Log out of hub-half

 

 

netstat dn

Display statistics for DataNET ports

 

 

password password

Change login password for hub-half

password

 

 

 

port start port

Start (or re-start) DataNET on a port

 

 

port stop port

Stop DataNET on a port (takes a port out of

 

service, e.g. for testing)

 

 

reset

Reset a hub-half

 

 

test port

Put a port into hardware test mode

 

 

test off

Turn off test mode

 

 

timeout on

Enable user login timeout

 

 

timeout off

Disable user login timeout

 

 

trace

Display current trace settings.

 

 

trace on

Enable frame tracing (start adding selected

 

frames to event buffer)

 

 

trace off

Disable frame tracing

 

 

trace port, port, ... port

Select ports for frame tracing

 

 

trace filter

Set filter mode for tracing

 

 

trace xxx.xxx.xxx.xxx

Set IP address filter for tracing

 

 

trace ports filter

Set trace port list and filter mode in the same

 

command

 

 

validation timeout

Set the link validation timeout

 

 

verbose on

Enable verbose event display

 

 

verbose off

Enable single-line summary event display

 

 

70 Command Summary