DataNET Hub Specifications, Continued
Communication | The Table below compares key communication features between using  | |||||
Comparisons | Advance Data Hiway, Ethernet, or DataNET.  | 
  | 
  | |||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Feature  | 
  | Advance Data Hiway  | Ethernet  | DataNET  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Speed  | 
  | 14.2 KB/Sec  | 10 M baud  | 2. 048 M baud  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Redundant  | 
  | Yes  | No  | Yes  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | Number of Units in  | 248  | 1200  | 1200  | 
  | |
  | Maxum System  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
DataNET Cable
The following Table should be used when evaluating or selecting cable for an existing or new DataNET installation.
Cable Type | Vendors & P/N | Installation Notes | |
  | 
  | 
  | |
Fiber Optic  | SAA P/N   | New Installation as an al-  | |
MM 62.5/125; 2 Fiber Conductors  | Industry Available from Mul-  | ternative to copper cable  | |
Max distance from Analyzer  | |||
  | tiple Vendors  | ||
  | 
  | to Hub or between Hubs  | |
  | 
  | 1520 meters (5000 ft)  | |
  | 
  | 
  | |
2- Conductor Copper Wire  | SAA P/N   | Recommended for Single  | |
  | Belden P/N 9182  | Channel  | |
  | Max distance from Analyzer  | ||
  | for  | ||
  | Belden Armored Cable or-  | to Hub or between Hubs  | |
  | der  | 1520 meters (5000 ft)  | |
  | SAA P/N   | 
  | |
  | 
  | 
  | |
SAA P/N   | Recommended for Dual  | ||
  | Belden P/N SSD1743  | Channel  | |
  | Max distance from Analyzer  | ||
  | 
  | ||
  | 
  | to Hub or between Hubs  | |
  | 
  | 1520 meters (5000 ft)  | |
  | 
  | 
  | |
Ethernet Cat 5 Unshielded Twisted  | SAA P/N   | Recommended for short  | |
pair (UTP)  | Industry Available from Mul-  | distances or within shelters.  | |
  | Max distance from analyzer  | ||
  | tiple Vendors  | ||
  | 
  | to hub or between hubs 600  | |
  | 
  | meters (2000 ft)  | |
  | 
  | 
  | 
Introduction • 9  |