Ethernet Connections, Continued

10BASE-T Cable Requirements

1.The 10BASET data cable requires a minimum of two twisted pairs (transmit pair and a receive pair). The type wire used should conform to the AT&T D-inside wire (DWI & PDS), or IBM Type 3, or Category 3 or 5 data grade or equivalent specifications.

2.The maximum length of a 10BASET data cable can not exceed 328 feet (100 meters). Typically to increase the distance each DNH will connect to a hub or other type of repeater/medium converter.

3.The cable should be terminated at both ends with RJ-45 STP male connectors. The table below shows the RJ-45 wiring connections for the DNH end of the cable.

 

Pin No.

MDI Function

 

 

1

TX+

 

 

2

TX-

 

 

3

RX+

 

 

4

NC

 

 

5

NC

 

 

6

RX-

 

 

7

NC

 

 

8

NC

 

 

 

 

 

46 Installation

2000585-001

Page 54
Image 54