Site Wiring Requirements, Continued

DataNET Channels

The DataNET channel connections can be either copper wire or fiber optic cable. The wiring method and cable type for DataNET is dependent upon the site requirements. For cable requirements see Table 2-1.

Table 2-1.

The following Table should be used when evaluating or selecting cable

Recommended DataNET

for an existing or new DataNET installation.

 

Cable

 

 

 

 

Cable Type

Vendors & P/N

Installation Notes

 

 

 

 

 

Fiber Optic

SAA P/N 1270002-002

New Installation as an

 

MM 62.5/125; 2 Fiber

Industry Available from

alternative to copper

 

cable

 

Conductors

Multiple Vendors

 

Max distance from Ana-

 

 

 

 

 

 

lyzer to Hub or between

 

 

 

Hubs 1520 meters

 

 

 

(5000 ft)

 

 

 

 

 

2- Conductor Copper

SAA P/N 1686002-001

Recommended for Sin-

 

Wire

Belden P/N 9182

gle Channel

 

 

Max distance from Ana-

 

 

for

 

 

Belden Armored Cable

lyzer to Hub or between

 

 

order

Hubs 1520 meters

 

 

SAAI P/N 1680000-002

(5000 ft)

 

 

 

 

 

4-Conductor Copper

SAA P/N 1681000-003

Recommended for Dual

 

Wire

Belden P/N SSD1743

Channel

 

 

Max distance from Ana-

 

 

 

 

 

 

lyzer to Hub or between

 

 

 

Hubs 1520 meters

 

 

 

(5000 ft)

 

 

 

 

 

Ethernet Cat 5 Un-

SAA P/N 1681003-006

Recommended for

 

shielded Twisted pair

Industry Available from

short distances or

 

(UTP)

within shelters.

 

Multiple Vendors

 

 

Max distance from ana-

 

 

 

 

 

 

lyzer to hub or between

 

 

 

hubs 600 meters (2000

 

 

 

ft)

 

 

 

 