Command Descriptions, Continued

“validation timeout” Command

sets up tracing on downstream port 2, for input data only.

trace crosslink output

sets up tracing of frames sent on the cross-link.

The filter may also specify frames for a specific station by declaring an IP address. The station filter cannot be combined with the port specifica- tion in a single command. To collect data from or to a station the com- mands would look like:

trace 9

trace 172.16.9.201

trace on

The first command specifies the upstream port for trace data. The sec- ond command filters the trace data to a single station’s frames, and the third command enables tracing.

Finally, the trace parameters may be reset to their default values (tracing all frames on the Ethernet port, without any address filtering) with:

trace reset

This command sets the time, in seconds, that the hub-half will wait for the “link validation” diagnostics to complete.

validation timeout

 

With no parameters, the com-

 

 

mand displays the current link

 

 

test timeout setting.

validation timeout

1000

Allows 1 second for the link di-

 

 

agnostics to complete.