Command Descriptions, Continued

“test” Command

“timeout” Command

This command places a selected port into a hardware diagnostic mode. The command

test 4

places port 4 into test mode. The hub will generate poll messages on port 4. All other ports continue to operate normally. The command

test off

turns off test mode. Only one port at a time may be in test mode.

This command may be used to disable the user login timeout. Normally, if a user has not issued a CLI command for five minutes, the hub-half will automatically shut down the user’s login session. This command may be used to defeat (and re-enable) this timeout:

timeout off

Disables timeout. The hub-half will not auto-

 

matically log out the user, regardless of the time

 

elapsed since the user last issued a CLI com-

 

mand.

timeout on

Re-enables the five-minute CLI timer.

2000585-001

Command Summary 81

Page 89
Image 89