Signal Equalizer Settings for Non Recommended Cable or Unknown Cable Lengths, Continued

 

Step

 

 

Action

 

 

 

 

 

 

 

 

3. cont

The next strongest signal is on port 6. 4.8/1.25 = 3.84

.

 

20 log of 3.84 = 11.7 dB

 

 

 

 

 

 

 

or

 

 

 

 

ratio of 3.84

 

 

Since this signal is 11.7 dB stronger than the signal on port 4,

 

 

the attenuator board on port 6 needs to be set to selection 5

 

 

(11 dB loss). This should put this signal at about 0.7 dB

 

 

above the signal on port 4. (Selection 6 could also be used

 

 

for 12.3 dB loss if several of the other boards had been set

 

 

for signals slightly below the port 4 signal level.)

 

 

 

 

 

 

 

4.

Ensure that the responses on all ports are within 3 dB of each

 

 

other

 

 

 

 

 

Example:

 

 

 

 

 

 

 

 

 

 

 

 

 

Port #

Resulting signal level refer-

 

 

 

 

enced to port 4

 

 

 

 

 

 

 

 

 

 

 

1

+ 2.1 dB

 

 

 

 

 

 

 

 

 

2

- 0.6 dB

 

 

 

 

 

 

 

 

 

4

0 dB

 

 

 

 

 

 

 

 

 

6

+ 0.7 dB

 

 

 

 

 

 

 

 

 

8

+ 0.1 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000585-001

Installation 41