Connector Panel Configuration

The unit comes standard with connectors for one channel of Y/PB/PR or GBR. By adding the optional decoder adaptor or input expansion adaptors, the input/ output connector panel can be assembled in a wide variety of configurations. The signals that each of the adaptors’ connectors supports are given in the table below. The type of signal to be applied to each input/ output connector is set with the INPUT CONFIGURATION menu.

Notes

One BKM-22X can be attached simultaneously with the BKM-20D or BKM-21D.

The BKM-20D, BKM-21D and BKM-22X can not provide proper active-through outputs if a signal whose format is not selected in the INPUT CONFIGURATION menu is input. (If AUTO is selected, input a signal which has the same format with the signal monitored last.)

For information about the INPUT CONFIGURATION menu, see “ [C1] Setting the Input Configuration (SET UP 1)

— INPUT CONFIGURATION Menu” on page 35.

Priority of the decoder adaptors

When multiple decoder adaptors for NTSC or PAL format are installed, their priority is as in the following table.

Example: To monitor the composite NTSC signal when the BKM-24N and BKM-27T are installed, the input composite NTSC signal is always decoded by the BKM-24N.

Input signal and

Decoder adaptor

 

 

 

 

 

 

its format

 

BKM-24N

BKM-25P

BKM-27T

BKM-21D

 

 

 

 

 

 

 

 

Composite

NTSC

1

 

3

2

signal

PAL

 

1

3

2

 

 

 

 

 

 

YC

NTSC

1

 

2

 

signal

PAL

 

1

2

 

 

 

 

 

 

 

 

Adaptor

BKM-41HD BKM-42HD

BKM-48X1)

 

name

HD SDI

HD SDI

HD

Signal

Input

Input

Analog

Adaptor

Adaptor

Expansion

format

 

 

Adaptor

 

 

 

 

Serial

Component

 

 

 

digital

525/625

 

 

 

input

Composite

 

 

 

 

NTSC

 

 

 

 

Composite

 

 

 

 

PAL

 

 

 

 

HD SDI

 

 

 

Analog Composite input NTSC

Composite

PAL

Composite

PAL-M

Composite

SECAM

YPBPR 525/625

GBR 525/625

Y/C

NTSC

Y/C

PAL

Y/C

PAL-M

YPBPR/GBR 1080/48I

YPBPR/GBR 1080/50I

YPBPR/GBR 575/50P

YPBPR/GBR 480/60P

YPBPR/GBR 1035/60I

YPBPR/GBR 1080/60I

YPBPR/GBR

 

 

 

720/60P

 

 

 

Number of digital

1

2

inputs

 

 

 

Number of analog

1

1

6

input

 

 

 

Signal can be reproduced with this adaptor. Signal can be reproduced when using this adaptor together with an adaptor marked with .

1)Equipped with floating/non-floating ground mode selected for hum reduction.

(continued)

Overview 1 Chapter

7