[C721] SET PROBE ON CURSOR

To perform adjustment, operate the BKM-14L as follows:

(1)Place the BKM-14L to the cursor displayed on the bottom left of the screen. ÷The adjustment starts. “IN PROGRESS” appears during adjustment, and the cursor is displayed at the next adjustment point when the adjustment is completed.

(2)Move the BKM-14L to the cursor. ÷The next adjustment is performed.

In the same way, adjust each adjustment point guided by the cursor. When the adjustment of all the points is completed, the screen automatically returns to the WHITE UNIFORMITY menu (1/2) ([C7]).

To cancel the adjustment

Press the MENU button. The adjusted data is cleared and the screen returns to the WHITE UNIFORMITY menu (1/2) ([C7]).

If the BKM-14L is not placed to the cursor

The following message appears, and the cursor moves to the right and left alternately on the screen.

DO YOU WISH TO ABORT?

LEFT CURSOR: ABORT

RIGHT CURSOR: CONTINUE

To abort, place the BKM-14L to the cursor when it is displayed on the left. ÷Returns to [C7].

To continue, place the BKM-14L to the cursor when it is displayed on the right. ÷Returns to [C721].

[C73] MANUAL menu

Adjust the gain of R, G and B with the MANUAL knobs.

The signal format and screen size for the adjustment are displayed on the top of the screen.

ADJUST... : Adjust the gain. ÷[C731] (It may take some time to change to the next menu.)

Use appropriate knobs and buttons in each adjustment as described below.

RED: CONTRAST KNOB: Adjust the R gain with the CONTRAST knob.

GREEN: BRIGHT KNOB: Adjust the G gain with the BRIGHT knob.

BLUE: CHROMA KNOB: Adjust the B gain with the CHROMA knob.

CURSOR POSITION: 10KEY: Move the cursor using the numeric keypad (except the 5 button) as illustrated below. Turn on/off the cursor using the 5 button.

The cursor moves in

1

2

3

 

 

 

the direction of the

 

 

 

arrow corresponding

4

5

6

to the pressed button.

 

 

 

 

7

8

9

CURSOR H SIZE: Specify the horizontal size of the cursor (1 to 4).

CURSOR V SIZE: Specify the vertical size of the cursor (1 to 4).

[C731] ADJUST menu

Adjust the gain at the cursor position using the CONTRAST (RED), BRIGHT (GREEN) and CHROMA (BLUE) knobs. Move the cursor using the numeric keypad.

To reset RED/GREEN/BLUE to the value before adjustment

When you are adjusting the gain using the MANUAL adjustment knobs, you can reset the setting to the one before adjustment by pressing the corresponding MANUAL button.

To cancel the adjustment

Press the MENU button. The adjusted data is cleared and the screen returns to [C73]. (It may take some time to change to the previous menu.)

When you want to erase characters from the screen while adjusting manually

Press the [F1] button. The characters disappear. To display characters, press the [F1] button again.

[C74] AUTO FULL POINTS menu

Before entering the AUTO FULL POINTS menu, connect the BKM-14L to the OPTION connector. The following message appears.÷[C741] (It may take some time to change to the next menu.)

SET PROBE ON CURSOR

[C741] SET PROBE ON CURSOR

To perform adjustment, operate the BKM-14L as follows:

(1)Place the BKM-14L to the cursor displayed in the center of the screen. ÷The adjustment starts. When the adjustment is completed, the cursor is displayed at the next adjustment point.

(2)Move the BKM-14L to the cursor. ÷The next adjustment is performed.

Menu 2 Chapter

(continued) 53