[C7] Adjusting Beam Landing and Digital Uniformity (SET UP 7)
— WHITE UNIFORMITY Menu
Menu 2 Chapter
In the same way, adjust each adjustment point guided by the cursor. When the adjustment of all the points is completed, the screen automatically returns to the WHITE UNIFORMITY menu (2/2) ([C7]).
To cancel the adjustment
Press the MENU button. The adjusted data is cleared and the screen returns to the WHITE UNIFORMITY menu (2/2) ([C7]). (It may take some time to change to the previous menu.)
If the
The following message appears, and the cursor moves to the right and left alternately on the screen.
DO YOU WISH TO ABORT?
LEFT CURSOR: ABORT
RIGHT CURSOR: CONTINUE
To abort, place the
To continue, place the
[C75] AUTO ONE POINT menu
Before entering the AUTO ONE POINT menu, connect the
CURSOR POSITION: 10KEY: Move the cursor using the numeric keypad (except the 5 button). Turn on/off the cursor using the 5 button.
TO CANCEL: MENU KEY: Press the MENU button to clear the adjusted data and return to the previous menu.
TO CONFIRM: ENTER KEY: Press the ENTER or Ent button to confirm the adjusted data.
To perform adjustment, operate the
(1)Move the cursor to the desired point using the
numeric keypad (except the 5 button), and press the ENTER or Ent button. ÷The following message appears and the cursor returns to the center.
SET PROBE ON CURSOR
Note
(2)Place the
(3)Move the
To adjust another point of the screen
Move the cursor to the desired point using the numeric keypad (except the 5 button), and press the ENTER or Ent button. Then place the
To finish the adjustment
When the adjustment of the specified points is completed, press the ENTER or Ent button without operating the numeric keypad. The adjusted data is stored in the memory and the screen returns to the WHITE UNIFORMITY menu (2/2) ([C7]). (It may take some time to change to the previous menu.)
Note
Operating the numeric keypad before pressing the ENTER or Ent button starts the adjustment.
To cancel the adjustment
Press the MENU button. The adjusted data is cleared and the screen returns to the WHITE UNIFORMITY menu (2/2) ([C7]). (It may take some time to change to the previous menu.)
If the
The following message appears, and the cursor moves to the right and left alternately on the screen.
DO YOU WISH TO ABORT?
LEFT CURSOR: ABORT
RIGHT CURSOR: CONTINUE
To abort, place the
To continue, place the
If you press the ENTER or Ent button without moving the cursor, the screen returns to the WHITE UNIFORMITY menu (2/2) ([C7]).