[C6] Adjusting Geometry and Convergence (SET UP 6) — ALIGNMENT Menu

Menu 2 Chapter

[C61] CONV FINE ADJUST menu (BVM-

D32E1WU/D32E1WE/D32E1WA only) Adjust the convergence finely at each adjustment point on the screen with the MANUAL knobs.

The signal format and screen size for the adjustment are displayed on the top of the screen.

ADJUST... : Adjust the convergence. ÷[C611] (It may take some time to change to the next menu.) Use appropriate knobs and buttons in each adjustment as described below.

H CONV: CONTRAST KNOB: Adjust the horizontal convergence with the CONTRAST knob.

H G CONV: BRIGHT KNOB: Adjust the horizontal convergence with the BRIGHT knob.

V CONV: CHROMA KNOB: Adjust the vertical convergence with the CHROMA knob.

V G CONV: PHASE KNOB: Adjust the vertical convergence with the PHASE knob.

CURSOR POSITION: 10KEY: Move the cursor using the numeric keypad (except the 5 button) as illustrated below. Turn on/off the cursor using the 5 button.

The cursor moves in

1

2

3

 

 

 

the direction of the

 

 

 

arrow corresponding

4

5

6

to the pressed button.

 

 

 

 

7

8

9

TO CANCEL: MENU KEY: Press the MENU button to clear the adjusted data and return to the previous menu.

TO CONFIRM: ENTER KEY: Press the ENTER or Ent button to confirm the adjusted data.

[C611] ADJUST menu

Adjust the convergence at the cursor position using the CONTRAST (H CONV), BRIGHT (H G CONV), CHROMA (V CONV) and PHASE (V G CONV) knobs. Move the cursor using the numeric keypad.

H CONV: Turn the CONTRAST knob clockwise to move the R beam to the right and the B beam to the left; counterclockwise to move the R beam to the left and the B beam to the right.

 

 

 

 

Turn

Turn

 

 

 

 

counterclockwise.

clockwise.

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

G

 

 

 

 

R G B

B

B G R

H G CONV: Turn the BRIGHT knob clockwise to move the G beam to the left; counterclockwise to move the G beam to the right.

TurnTurn

counterclockwise. clockwise.

B GR

B G R

B G R

V CONV: Turn the CHROMA knob clockwise to move the R beam upward and the B beam downward; counterclockwise to move the R beam downward and the B beam upward.

TurnTurn

counterclockwise. clockwise.

BR RGB

GG

RB

V G CONV: Turn the PHASE knob clockwise to move the G beam downward; counterclockwise to move the G beam upward.

 

Turn

Turn

R

counterclockwise.

clockwise.

R

 

R

 

G

G

 

G

 

B

B

 

 

B

 

To reset the convergence to the condition before adjustment

You can reset the adjusted condition to the one before adjustment by pressing the corresponding MANUAL button.

To finish the adjustment

Press the ENTER or Ent button. The adjusted data is stored in the memory and the screen returns to the CONV FINE ADJUST menu ([C61]). (It may take some time to change to the previous menu.)

To cancel the adjustment

Press the MENU button. The adjusted data is cleared and the screen returns to [C61]. (It may take some time to change to the previous menu.)

When you want to erase characters from the screen while adjusting the convergence

Press the [F1] button. The characters disappear. To display characters, press the [F1] button again.