[C2] Assigning the Remote Control Functions (SET UP 2) — REMOTE Menu

Menu 2 Chapter

Overview

The remote control functions are set with the REMOTE menu. With this monitor, both serial remote control (REMOTE 1) and parallel remote control (REMOTE 2) are possible.

The following settings can be made with the REMOTE menu.

Settings for the serial remote control (REMOTE

1)(REMOTE 1 CONFIG menu)

An address number (MONITOR ADDRESS) and group number (GROUP ADDRESS) can be assigned to the monitor connected to the serial REMOTE 1 connector.

The BVM-xxE/F/G, BVM-Dxx and HDM-xxE series monitors can be connected.

Settings for the parallel remote control (REMOTE

2)(REMOTE 2 CONFIG menu)

Functions can be assigned to the pins of the REMOTE 2 connector.

ON/OFF setting for the parallel remote control (REMOTE 2) (REMOTE 2 menu)

Priority order of the remote control functions It is possible to simultaneously use the BKM-10R/11R Monitor Control Unit, REMOTE 1, and REMOTE 2 for control, but commands from REMOTE 2 have priority. Therefore, it is impossible for the BKM-10R/ 11R or REMOTE 1 to change items set by REMOTE 2. There is no priority order between commands from REMOTE 1 and the BKM-10R/11R control panel.

About monitor address and group numbers

The BKM-10R/11R Monitor Control Units are able to control up to 32 monitors connected via serial remote connector (using the REMOTE 1 connector). By giving each monitor a monitor address and group number, it is possible to control just a specific monitor or monitor group.

With the REMOTE 1 CONFIG menu, each monitor can be set with a monitor address and group number, between 1 and 99.

The ADDRESS menu is used to select a particular monitor or group by entering a monitor number or group number.

For information about the ADDRESS menu, see “Selecting the Monitor to Control — ADDRESS Menu” on page 60.

Note

The address number must differ from one monitor to another. If two or more monitors have the same address number, an operation error occurs.

Structure of the REMOTE Menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Level 1

 

Level 2

 

 

 

 

Level 3

 

Level 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT CONFIGURATION C1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE C2

 

 

REMOTE 1 CONFIG

 

 

 

 

 

MONITOR ADDRESS

 

 

 

 

 

 

C21

 

 

 

 

 

 

 

 

PASSWORD C3

 

 

 

 

 

 

 

 

GROUP ADDRESS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM CONFIGURATION C4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON SCREEN SET C5

 

REMOTE 2 CONFIG

 

 

 

 

 

 

1 PIN

 

 

 

 

 

CH (1/2)

 

 

 

 

C22

 

 

 

 

 

 

C221

 

 

 

 

ALIGNMENT C6

 

REMOTE 2

 

 

 

 

2 PIN

 

 

 

 

BLUE ONLY (2/2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE UNIFORMITY C7

 

 

 

 

 

 

 

 

3 PIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTEND MENU C8

 

 

 

 

 

 

 

 

4 PIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 PIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 PIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 PIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 PIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40