[A1] PRESET menu/CH SET menu Select the setting method.

MANUAL... : Set with the MANUAL knobs. ÷[A11]

AUTO... : Set by automatic adjustment. ÷[A12]

COPY FROM... : Copy data from elsewhere. ÷[A13]

[A2] MATRIX menu

Select the data area for the YPBPR (SMPTE/EBU-N10), SDI 4:2:2 and HD SDI signals. The ITU 709, ITU 601 or SMPTE 240M can be selected for each signal format. The selected data area is common to all the channels. The factory settings are as follows:

1080/60I: ITU 709 (default)

1080/50I: ITU 709 (default)

1080/48I: ITU 709 (default)

1035/60I: SMPTE 240M (default)

720/60P: ITU 709 (default)

575/50P: ITU 601 (default)

575/50I: ITU 601 (default)

480/60P: ITU 601 (default)

480/60I: ITU 601 (default)

Notes

When PRESET is selected, the same MATRIX data as the above are used automatically.

The ITU 601 data is used for the COMPOSITE, YC, YPBPR (BETACAM), GBR and SDI (D2) signals, regardless of the settings on the MATRIX menu.

[A11] MANUAL menu

Adjust values by turning the PHASE, CHROMA, BRIGHT, and/or CONTRAST knobs. After the adjustment, press the ENTER or Ent button to confirm the adjusted values.

PHASE: xxxx

BRIGHT: xxxx

CHROMA: xxxx

CONTRAST: xxxx

When you want to erase characters from the screen while adjusting manually

Press the [F1] button. The characters disappear. To display characters, press the [F1] button again.

To reset the setting to the default

Press the corresponding MANUAL button. The adjusted value is reset to 1000 (default).

[A12] AUTO menu

Select the color bar signal to be used for automatic adjustment. ÷Adjustment is carried out.

8COLOR BAR 100%: 100% full-field 8-color bar (white, yellow, cyan, green, magenta, red, blue and black)

8COLOR BAR 75%: 75% full-field 8-color bar (with 100% white signal, effective for 15K signal only)

7COLOR BAR 100%: 100% full-field 7-color bar (white, yellow, cyan, green, magenta, red and blue) (with 100% white signal, not selectable for 15K signal)

SMPTE COLOR BAR: SMPTE standard color bar (effective for 15K signal only)

EIA COLOR BAR: EIA standard color bar (effective for 15K signal only)

Note

When you execute the AUTO menu, SYNC button should be set to OFF (INT SYNC).

EXT SYNC will cause an error abortion of auto adjustment procedure.

[A13] COPY FROM menu

Select the source to be copied from.

OTHER VALUE... : Copy data from another channel or common data. ÷[A131]

OTHER MONITOR... : Copy data from another monitor. ÷[A132]

MEMORY CARD... : Copy data from a memory card. ÷[A133]

[A131] OTHER VALUE menu Choose either PRESET or CH SET.

÷Copy is carried out. PRESET: Copy common data.

CH SET: Copy data set for another channel. Input the number of the channel from which the data will be copied.

[A132] OTHER MONITOR menu

Input the address of the monitor from which the data will be copied. ÷[A1321]

MONITOR ADDRESS: Input the address number.

[A1321] MONITOR ADDRESS menu Choose either PRESET or CH SET.

÷Copy is carried out. PRESET: Copy common data.

CH SET: Copy data set for another channel. Input the number of the channel from which the data will be copied.

[A133] MEMORY CARD menu

Select the file name. ÷[A1331]

FILE NAME: Select the file name.

Note

The input signal is not displayed during the data loading.

[A1331] FILE NAME menu Choose either PRESET or CH SET.

÷Copy is carried out. PRESET: Copy common data.

CH SET: Copy data set for another channel. Input the number of the channel from which the data will be copied.

Menu 2 Chapter