[A1] PRESET menu/CH SET menu Select the setting method.
MANUAL... : Set with the MANUAL knobs. ÷[A11]
AUTO... : Set by automatic adjustment. ÷[A12]
COPY FROM... : Copy data from elsewhere. ÷[A13]
[A2] MATRIX menu
Select the data area for the YPBPR
1080/60I: ITU 709 (default)
1080/50I: ITU 709 (default)
1080/48I: ITU 709 (default)
1035/60I: SMPTE 240M (default)
720/60P: ITU 709 (default)
575/50P: ITU 601 (default)
575/50I: ITU 601 (default)
480/60P: ITU 601 (default)
480/60I: ITU 601 (default)
Notes
•When PRESET is selected, the same MATRIX data as the above are used automatically.
•The ITU 601 data is used for the COMPOSITE, YC, YPBPR (BETACAM), GBR and SDI (D2) signals, regardless of the settings on the MATRIX menu.
[A11] MANUAL menu
Adjust values by turning the PHASE, CHROMA, BRIGHT, and/or CONTRAST knobs. After the adjustment, press the ENTER or Ent button to confirm the adjusted values.
PHASE: xxxx | BRIGHT: xxxx |
CHROMA: xxxx | CONTRAST: xxxx |
When you want to erase characters from the screen while adjusting manually
Press the [F1] button. The characters disappear. To display characters, press the [F1] button again.
To reset the setting to the default
Press the corresponding MANUAL button. The adjusted value is reset to 1000 (default).
[A12] AUTO menu
Select the color bar signal to be used for automatic adjustment. ÷Adjustment is carried out.
8COLOR BAR 100%: 100%
8COLOR BAR 75%: 75%
7COLOR BAR 100%: 100%
SMPTE COLOR BAR: SMPTE standard color bar (effective for 15K signal only)
EIA COLOR BAR: EIA standard color bar (effective for 15K signal only)
Note
When you execute the AUTO menu, SYNC button should be set to OFF (INT SYNC).
EXT SYNC will cause an error abortion of auto adjustment procedure.
[A13] COPY FROM menu
Select the source to be copied from.
OTHER VALUE... : Copy data from another channel or common data. ÷[A131]
OTHER MONITOR... : Copy data from another monitor. ÷[A132]
MEMORY CARD... : Copy data from a memory card. ÷[A133]
[A131] OTHER VALUE menu Choose either PRESET or CH SET.
÷Copy is carried out. PRESET: Copy common data.
CH SET: Copy data set for another channel. Input the number of the channel from which the data will be copied.
[A132] OTHER MONITOR menu
Input the address of the monitor from which the data will be copied. ÷[A1321]
MONITOR ADDRESS: Input the address number.
[A1321] MONITOR ADDRESS menu Choose either PRESET or CH SET.
÷Copy is carried out. PRESET: Copy common data.
CH SET: Copy data set for another channel. Input the number of the channel from which the data will be copied.
[A133] MEMORY CARD menu
Select the file name. ÷[A1331]
FILE NAME: Select the file name.
Note
The input signal is not displayed during the data loading.
[A1331] FILE NAME menu Choose either PRESET or CH SET.
÷Copy is carried out. PRESET: Copy common data.
CH SET: Copy data set for another channel. Input the number of the channel from which the data will be copied.
Menu 2 Chapter