Overview 1 Chapter

Location and Function of Parts

6DEGAUSS button

Press to degauss the CRT (every time the monitor is turned on, the CRT is degaussed automatically). To degauss again, wait for more than five minutes.

7DISPLAY UNIT connector (rear)

Connect to the CONTROL UNIT connector of the monitor, using an optional RCC-5G/10G/30G cable or the cable supplied with the BKM-32H or BKM-34H Monitor Control Unit Attachment Kit.

The power is supplied from the monitor and the control signal is sent and received via this connector.

8Numeric keypad

Use to designate the channel number for the input signal to be monitored, or to enter the setting values with the menus.

9MANUAL adjustment buttons and knobs Each press of one of these buttons turns the button’s green LED on or off. When the corresponding button is on (lit), it is possible to manually adjust the contrast, brightness, chroma and phase by turning the corresponding knobs. The PHASE knob is also used to enter the setting values with the menus. It is possible to set the preset value for each adjusting item with the CONTROL PRESET ADJ menu.

 

CHROMA

BRIGHT

CONTRAST

PHASE button

button

button

button and

and knob

and knob

and knob

knob

INPUT

1 2 3 Del

4

5

6

0

7 8 9 Ent

Del button: Deletes the values and characters entered.

Numeric buttons

Ent button: Confirms the values and characters entered (ENTER button of the menu operation buttons 4 has the same function).

PHASE

CHROMA

BRIGHT

CONTRAST

MANUAL

MANUAL

MANUAL

MANUAL

For information about the CONTROL PRESET ADJ menu, see “ [A] Preset Adjustment of the Picture Level Control Knobs — CONTROL PRESET ADJ menu” on page 28.

Notes

Channel number entry method

When selecting a channel number from 1 to 9, press one-digit channel number on the numeric keypad. When selecting a channel number from 10 to 99, press 0 button, then press the two-digit channel number.

The signal phase cannot be adjusted when using the composite SECAM, composite PAL D, component or SDI (component or composite serial digital interface) format.

The phase and chroma cannot be adjusted when using GBR signals.

16