BAdjusting the Color Temperature — COLOR TEMP ADJ MenuSetting Lists in the COLOR TEMP ADJ Menu

2 Chapter Menu

This section explains the setting lists displayed in the menu.

How to read the setting lists

For purposes of explanation, each setting list is preceded by a menu number. These numbers are not displayed on the screen.

For more information about the menu number, see “About menu numbers” on page 23.

The arrow mark () refers you to another setting list that appears after you make the setting, or to an operation that is carried out as a result of the setting. When there is no arrow mark, the menu does not have any sub-list.

[B]COLOR TEMP ADJ menu

Select STD, COL 1, COL2, or CH SET. ⎟ [B1] STD: Use common data (factory setting: D65). COL1: Use common data (factory setting: D93). COL2: Use common data (factory setting: D56/D651)). CH SET: Use data for each individual channel

(factory setting: D65). Use the numeric keypad to select the desired channel.

[B1] STD/COL1/COL2/CH SET menu Select the adjustment method.

MANUAL... : Set with the MANUAL knob. ⎟ [B11]

PROBE... : Set using a probe. ⎟ [B12]

COPY FROM... : Copy data from elsewhere.

[B13]

TRIM... : Perform fine adjustments after setting the color temperature. ⎟ [B14]

[B11] MANUAL menu Select the adjustment method.

ADJUST... : Adjust the gain and bias. To shift between gain adjustment and bias adjustment, press UP/DOWN buttons. Use appropriate knobs in each adjustment as described below. After the adjustment, press the ENTER or Ent button to confirm the adjusted values.

RED: CONTRAST KNOB (Adjust the R gain or bias with the CONTRAST knob.)

GREEN: BRIGHT KNOB (Adjust the G gain or bias with the BRIGHT knob.)

BLUE: CHROMA KNOB (Adjust the B gain or bias with the CHROMA knob.)

LUMINANCE: PHASE KNOB (Adjust luminance with the PHASE knob.)

To reset RED/GREEN/BLUE to the value before adjustment

When you are adjusting the gain or bias using the MANUAL adjustment knobs, you can reset the setting to the one before adjustment by pressing the corresponding MANUAL button.

To reset all of settings at the same time, press the PHASE button.

Note

You cannot reset the setting after you press the ENTER or Ent button.

ORIGINAL VALUE... : Set the initial value. STD: Use common data (factory setting: D65). COL1: Use common data (factory setting: D93). COL2: Use common data (factory setting: D56/ D651)).

CH SET: Use data for a particular channel

(factory setting: D65).

SIGNAL: Select the white signal to be used for adjustment.

INT: Use an internal signal. Simultaneously with the adjustment of the gain and bias, the 100 IRE and 20 IRE signals are automatically switched.

EXT: Use an external input signal. When adjusting the gain and bias, input the proper signal.

To access the MANUAL menu directly

When the [F2] button is assigned as the short-cut key to the MANUAL menu, you can directly access the MANUAL menu that corresponds to the color temperature setting (STD/COL1/COL2/CH SET) set to the image on the screen.

For details of how to assign the short-cut key, see “ [C4] Setting the Channel Selection Method, Power-Up Conditions and Decoder (SET UP 4) — SYSTEM CONFIGURATION Menu” on page 44.

[B12] PROBE menu

Select the probe for color temperature adjustment. SONY BKM-14L...:Use the BKM-14L.

[B121]

GRASEBY SLS 9400...: Use the SLS 9400.

[B122]

MINOLTA CA-100

...: Use the CA-100.

[B122]

PHILIPS PM 5639...

: Use the PM 5639.

[B122]

THOMA TF6...: Use the TF6. ⎟ [B122]

 

 

........................................................................................................................................................................................................

1) D56: BVM-D20F1U/D24E1WU/D32E1WU

32 D65: BVM-D20F1E/D20F1A/D24E1WE/D24E1WA/D32E1WE/D32E1WA