Overview 1 Chapter

Location and Function of Parts

7REMOTE 1 connectors (female, D-sub 9-pin)

REMOTE 1

IN

REMOTE 1 IN connector

 

OUT

REMOTE 1 OUT connector

 

Pin number

Function

 

 

1

Set input signal channel 1 (numeric keypad

 

function)

 

 

2

Set input signal channel 2 (numeric keypad

 

function)

3

Select sync signal (SYNC button function)

 

 

4

Set the screen to monochrome, or set for

 

automatic switching based on the input signal

 

(MONO MODE button function)

 

 

5

Safe area on/off (SAFE AREA button

 

function)

 

 

6, 7

Not connected

 

 

8

Tally lamp on/off

 

 

9

Ground

 

 

These are RS-485 serial interface connectors, used for connecting two or more BVM-Dxx, BVM-xxE/F/G and HDM-xxE series monitors.

The IN and OUT connectors form a loop-through connection.

Connect two monitors using a cable with D-sub 9-pin plugs such as an RCC-5G (not supplied) as shown in the figure.

Monitor 1

Monitor 2

REMOTE 1

REMOTE 1

IN

IN

OUT

OUT

Cable with D-sub 9-pin plugs (not supplied)

8REMOTE 2 connector (female, D-sub9-pin)Forms a parallel switch and controls the monitor externally. The pin assignment and factory setting function assigned to each pin are given below.

51

9 6

All pin function assignments can be changed with the REMOTE menu.

For information about the REMOTE menu, see “ [C2] Assigning the Remote Control Functions (SET UP 2) — REMOTE Menu” on page 40.

To switch each function between on and off or between enable and disable, change pin connections in the following way.

ON or enabled: Short each pin and pin 9 together.

OFF or disabled: Leave each pin open.

9ISR (Interactive Status Reporting) connector (female, D-sub 9-pin)

Connect to the ISR system.

CONTROL UNIT connector (female, D-sub 9- pin)

Connects the BKM-10R Monitor Control Unit using a cable with D-sub 9-pin plugs such as an RCC-5G/10G/ 30G (not supplied) or the cable supplied with the BKM-32H/34H Monitor Control Unit Attachment Kit.

14